Resolving RELABEL operation errors
If you run a RELABEL operation when all drives are busy, the target volume cannot be relabeled because it cannot obtain a drive. Busy drives are drives that are in use for regular operations such as backup, restore, migration, and reclamation.
When a RELABEL error occurs, the following example information
is produced:
ANR0984I Process 25 for RELABEL started in the BACKGROUND at 22:10:36.
ANR8799I RELABEL: Operation for library IBMVTL started as process 25.
ANR1341I Scratch volume 007403 has been deleted from storage pool VTLPOOL.
ANR8847E No LTO-type drives are currently available in library IBMVTL.
ANR8801I LABEL LIBVOLUME process 25 for library IBMVTL completed; 0 volume(s)
labeled, 0 volume(s) checked-in.
ANR0985I Process 25 for RELABEL running in the BACKGROUND completed with
completion state SUCCESS at 22:10:36.To resolve
a RELABEL error, complete the following steps:
- Ensure that one drive is kept available for the RELABEL operation and relabel a target volume.
- Update the device classes that point to the library. Update the
device classes with a MOUNTLIMIT parameter value
that is less than the total number of drives available.
If a RELABEL operation cannot obtain a drive or fails to relabel a volume, IBM Storage Protect tries to relabel the volume during each future RELABEL operation.
SEARCH=YES LABELSOURCE=BARCODE OVERWRITE=YES CHECKIN=SCRATCH