Switch specifications

Table 1 lists the environmental specifications for the switch.

Table 1. Environmental Specifications

Description

Specification

Temperature, ambient operating

32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10 to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

10 to 95%

Altitude, operating

-197 to 6500 ft (-60 to 2000 m)

Table 2 lists the physical specifications for the switch.

Table 2. Physical Specifications

Description

Specification

Dimensions (HxWxD)

1.72 x 17.3 x 18 in. (4.37 x 43.94 x 45.72 cm) excluding PSU and fan module handles

Rack Space

Chassis requires 1 RU (1.75 in. or 4.45 cm)

Weight

18.73 lb (8.5 kg) unpopulated

Fan Dimensions (WxH)

1.575 x 1.575 in. (4.0 x 4.0 cm)

Fan Slots Opening Dimensions (WxH)

1.614 x 1.602 in. (4.09 x 4.06 cm)

Power Supply

500-W
  • 500-W AC, port-side exhaust variant (up to 2 per switch)
  • 500-W AC, port-side intake variant (up to 2 per switch)
  • AC input—100 to 240 V AC (10% range)
  • Frequency—50 to 60 Hz (nominal)
  • 80 PLUS Platinum certified
1200-W
  • 1200W AC/ HVAC/ HVDC Bidirectional airflow (2 per switch)
  • Part Number: DS-CAC-1200W
  • AC input: 90V to 305V
  • DC input: 192V to 400V
  • Frequency – 50 to 60 Hz (nominal)

Airflow

  • Back to front (toward ports) using port-side exhaust fans
  • Front to back (into ports) using port-side intake fans
  • 50 CFM (0.02 m3/s) through system fan assembly at 25°C
  • 100 CFM (0.04 m3/s) maximum

We recommend that you maintain a minimum air space of 2.5 in. (6.4 cm) between walls and chassis air vents and a minimum horizontal separation of 6 in. (15.2 cm) between two chassis to prevent overheating.

To prevent the switch from overheating and shutting down, you must position the air intake for the switch in a cold aisle.