IBM Supervisor-1 module

The IBM Supervisor-1 module is designed specifically for the SAN192C-6 and SAN384C-6 chassis. This supervisor module provides control and management functions for the switch and enables high-performance switching.

This supervisor module supports the following features.

  • Nondisruptive software upgrades
  • Stateful process restart and failover
  • Fully redundant operation
  • Support for up to 384 Fibre Channel ports in a single chassis and 1152 Fibre Channel ports in a single rack
  • Support for up to 24 Tbps of Fibre Channel system bandwidth
  • Multipathing based on Fabric Shortest Path First (FSPF)
  • Ability to dynamically reroute traffic in the event of a switch failure
  • Network management through the command-line interface (CLI) and through Data Center Network Manager (DCNM)
  • Extensive security features including RADIUS and TACACS+, Fibre Channel Security Protocol (FC-SP), Secure File Transfer Protocol (SFTP), Secure Shell (SSH) Protocol, and Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES), VSANs, hardware-enforced zoning, ACLs, and per-VSAN role-based access control
  • Support for virtual SAN (VSAN) technology and inter-VSAN routing (IVR)
  • Network services such as access control lists (ACLs) and quality of service (QoS)
  • Smart zoning
  • Power-on self-test (POST) and diagnostics
  • Switched Port Analyzer (SPAN) and Remote Switched Port Analyzer (RSPAN)

Figure 1 shows the IBM c-type SAN switches and directors Supervisor-1 module.

Figure 1. IBM Supervisor-1 Module
  1. Module retaining screw
  2. ID: locator LED 
  3. Link: management port link status LED  
  4. MGMT Ethernet: system out of band Ethernet management port 
  5. ACT: management port packet activity LED    
  6. Console Serial Port: module serial console port   
  7. Eject Request: eject request button for USB1 device
  8. USB1: usb1 status LED 
  9. USB1 USB port   
  10. Slot0: slot0 status LED
  11. Eject Request: eject request button for slot0 device
  12. Reset: module reset button
  13. Module lock release button
  14. Status: system diagnostic test status LED
  15. System: system environment status LED
  16. Active: supervisor redundancy status LED
  17. PWR MGMT: system power status LED
  18. Management port operational status LED
  19. Module ejection lever
  20. Slot0 USB port
Table 1 describes the LEDs on the IBM c-type SAN switches and directors Supervisor-1 Module.
Table 1. IBM Supervisor-1 Module LEDs

LED

Status

Description

ID

Flashing blue

A user has activated this LED to allow a person to find this module in the chassis.

Off

Location identification is deactivated for this module.

Status

Green

All module diagnostics passed. The module is operational.

Red

Indicates one of the following conditions:

The module has detected an error and cannot power on or boot up.

The module is not properly inserted.

A bootup or runtime diagnostic test has failed.

Flashing Red

Indicates one of the following conditions:

The temperature of the module has exceeded the safe operating temperature limits (a major temperature alarm has occurred). The module has been shut down to prevent permanent damage. The system will be shut down after two minutes if this condition is not cleared.

The module is resetting.

The ejector lever is open.

Off

The module is not receiving power.

System

Green

All environmental sensors in the system are within operational bounds.

Amber

At least one power supply has failed or the power supply fan has failed.

Red

The temperature of the supervisor module exceeded the major threshold.

Active

Green

The supervisor is operational and in HA active state.

Amber

The supervisor module is in HA standby state.

Power Management

Green

There is sufficient power available for all installed modules.

Amber

There is insufficient power for all installed modules.

MGMT Ethernet

Green

The mgmt0 interface is administratively active and the supervisor is in HA active state.

Amber

The mgmt0 interface is administratively active and the supervisor is in the HA standby state.

Off

The mgmt0 interface is uninitialized. No signal is detected.

ACT

Green

Frames are being transmitted or received by the interface.

Off

There is no activity on the interface.

Link

Green

The management port link is operational.

Amber

The management port link has been disabled by software.

Flashing amber

The management port has been disabled by a hardware fault.

Off

No link signal received.

USB1

Green

The flash device is mounted.

Red

The device is a valid device type, but failed to be mounted. This can be due to an invalid file system format.

Off

The flash device is not mounted and can be safely removed.

Slot0

Green

The flash device is mounted.

Red

The device is a valid device type, but failed to be mounted. This can be due to an invalid file system format.

Off

The flash device is not mounted and can be safely removed.