Verification

Use this information to verify the migration procedure.

Use the following show commands to verify the migration procedure for the Supervisor-4 Module.
  • show version
  • show module
  • show interface brief
  • show interface status
  • show system redundancy status
The following sample output is from the show version command on the Supervisor-4 Module.
switch# show version

Nexus Operating System (NX-OS) Software 
TAC support: http://www.cisco.com/tac
Documents: 
http://www.cisco.com/en/US/products/ps9372/tsd_products_support_serie s_home.html
Copyright (c) 2002-2019, Cisco Systems, Inc. All rights reserved. 
The copyrights to certain works contained in this software are 
owned by other third parties and used and distributed under 
license. Certain components of this software are licensed under 
the GNU General Public License (GPL) version 2.0 or the GNU 
Lesser General Public License (LGPL) Version 2.1. A copy of each 
such license is available at 
http://www.opensource.org/licenses/gpl-2.0.php and 
http://www.opensource.org/licenses/lgpl-2.1.php

Software
BIOS:      version 2.6.0
kickstart: version 8.4(1)
system:    version 8.4(1)
BIOS compile time:      05/17/2019
kickstart image file is: bootflash:///m9700-sf4ek9-kickstart-mz.8.4.1.bin 
kickstart compile time:  6/30/2019 23:00:00 [06/15/2019 14:49:08]
system image file is:  
   bootflash:///m9700-sf4ek9-mz.8.4.1.bin system compile time: 
                      6/30/2019 23:00:00 [06/15/2019 16:15:18]


Hardware
SAN384C-6 (10 Slot) Chassis ("Supervisor Module-4") 
Intel(R) Xeon(R) CPU D-1548 with 14270332 kB of memory. 
Processor Board ID JAE22440CB1

Device name: switch 
bootflash:	3932160 kB
slot0:	0 kB (expansion flash)
Kernel uptime is 0 day(s), 0 hour(s), 36 minute(s), 9 second(s) 
Last reset
Reason: Unknown
System version: 8.4(1) 
Service:

plugin
Core Plugin, Ethernet Plugin 
Active Package(s)
The following sample output is from the show module command on the Supervisor-4 Module for a dual supervisor migration.
switch# show module

Mod	Ports	Module-Type	                        Model	             Status
---	-----	-----------------------------------	------------------	----------
1	  48	   1/10 Gbps Ethernet Module	          DS-X9848-480K9	     ok
2	  48	   2/4/8/10/16 Gbps Advanced FC Module	DS-X9448-768K9	     ok
3	  24	   40 Gbps FCoE Module	                DS-X9824-960K9	     ok
4	  48	   4/8/16/32 Gbps Advanced FC Module  	DS-X9648-1536K9	    ok
5	  0	    Supervisor Module-4	                DS-X97-SF4-K9	      active *
6	  0	    Supervisor Module-4	                DS-X97-SF4-K9	      ha-standby
7	  34	   1/10/40G IPS,2/4/8/10/16G FC Module	DS-X9334-K9	        ok
8	  48	   4/8/16/32 Gbps Advanced FC Module  	DS-X9648-1536K9    	ok
10	 48	   2/4/8/10/16 Gbps Advanced FC Module	DS-X9448-768K9	     ok
Mod     Sw         Hw
---    ---------   -----
1      8.4(1)      1.1
2      8.4(1)      1.3
3      8.4(1)      1.0
4      8.4(1)      1.0
5      8.4(1)      1.0
6      8.4(1)      1.0
7      8.4(1)      1.0
8      8.4(1)      1.0
10     8.4(1)      1.1


Mod       MAC-Address(es)                           Serial-Num
---	--------------------------------------    ----------
1         84-78-ac-1b-3d-58 to 84-78-ac-1b-3d-8b    JAF1718AAAD
2         f4-cf-e2-7c-cd-30 to f4-cf-e2-7c-cd-33    JAE1847038X
3         04-6c-9d-32-36-aa to 04-6c-9d-32-37-1b    JAE19330ASN
4         00-76-86-bf-58-23 to 00-76-86-bf-58-57    JAE203901ZG
5         00-2f-5c-fc-54-0a to 00-2f-5c-fc-54-1d    JAE22440CB1
6         00-2f-5c-fc-81-b4 to 00-2f-5c-fc-81-c7    JAE22490XKJ
7         00-da-55-a2-25-00 to 00-da-55-a2-25-0f    JAE195004XM
8         74-86-0b-33-c6-70 to 74-86-0b-33-c6-a4    JAE213101Q3
10        3c-0e-23-c5-53-d0 to 3c-0e-23-c5-53-d3    JAE180605X3

Mod    Online Diag Status
---    ------------------
1       Pass
2       Pass
3       Pass
4       Pass
5       Pass
6       Pass
7       Pass
8       Pass
10      Pass

Xbar Ports    Module-Type            Model	       Status
---  -----   -------------------    ---------------    ------------ 
1     0       Fabric Module 1       DS-X9710-FAB1      ok
2     0       Fabric Module 1       DS-X9710-FAB1      ok
3     0       Fabric Module 1       DS-X9710-FAB1      ok
4     0       Fabric Module 1       DS-X9710-FAB1      ok
5     0       Fabric Module 1       DS-X9710-FAB1      ok
6     0       Fabric Module 1       DS-X9710-FAB1      ok
Xbar   Sw       Hw
---    -----   -------
1      NA      1.0
2      NA      1.0
3      NA      1.0
4      NA      1.0
5      NA      1.0
6      NA      1.0

Xbar   MAC-Address(es)      Serial-Num
---   ---------------     ----------------- 
1       NA                 JAE222305VS
2       NA                 JAE2217096X
3       NA                 JAE222305V5
4       NA                 JAE2217096L
5       NA                 JAE2217096J
6       NA                 JAE222305V8

The following sample output is from the show inventory command on the Supervisor-4 Module.
switch# show inventory

NAME: "Chassis", DESCR: "SAN384C-6 (10 Slot) Chassis " 
PID: DS-C9710,  VID: V00 ,  SN: JAF1647AQTL

NAME: "Slot 1",  DESCR: "1/10 Gbps Ethernet Module" 
PID: DS-X9848-480K9,  VID: V01 ,  SN: JAF1718AAAD

NAME: "Slot 2", DESCR: "2/4/8/10/16 Gbps Advanced FC Module" 
PID: DS-X9448-768K9,  VID: V02 ,  SN: JAE1847038X

NAME: "Slot 3",  DESCR: "40 Gbps FCoE Module"
PID: DS-X9824-960K9,  VID: V00 ,  SN: JAE19330ASN

NAME: "Slot 4", DESCR: "4/8/16/32 Gbps Advanced FC Module" 
PID: DS-X9648-1536K9,  VID: V01 ,  SN: JAE203901ZG

NAME: "Slot 5",  DESCR: "Supervisor Module-3"
PID: DS-X97-SF1-K9,  VID: V02 ,  SN: JAE194005JC

NAME: "Slot 6",  DESCR: "Supervisor Module-3"
PID: DS-X97-SF1-K9,  VID: V02 ,  SN: JAE17440HVB

NAME: "Slot 7", DESCR: "1/10/40G IPS, 4/8/10/16G FC Module" 
PID: DS-X9334-K9,  VID: V00 ,  SN: JAE195004XM

NAME: "Slot 8", DESCR: "4/8/16/32 Gbps Advanced FC Module" 
PID: DS-X9648-1536K9,  VID: V01 ,  SN: JAE213101Q3

NAME: "Slot 10", DESCR: "4/8/10/16 Gbps Advanced FC Module" 
PID: DS-X9448-768K9,  VID: V01 ,  SN: JAE180605X3

NAME: "Slot 11",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE222305VS

NAME: "Slot 12",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE2217096X

NAME: "Slot 13",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE222305V5

NAME: "Slot 14",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE2217096L

NAME: "Slot 15",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE2217096J

NAME: "Slot 16",  DESCR: "Fabric card module"
PID: DS-X9710-FAB3,  VID: V00 ,  SN: JAE222305V8

NAME: "Slot 35", DESCR: "SAN384C-6 (10 Slot) Chassis Power Supply" 
PID: DS-CAC97-3KW,  VID: V01 ,  SN: DTM164602XH

NAME: "Slot 37", DESCR: "SAN384C-6 (10 Slot) Chassis Power Supply" 
PID: DS-CAC97-3KW,  VID: V01 ,  SN: DTM1649022W

NAME: "Slot 38", DESCR: "SAN384C-6 (10 Slot) Chassis Power Supply" 
PID: DS-CAC97-3KW,  VID: V01 ,  SN: DTM16490239

NAME: "Slot 39", DESCR: "SAN384C-6 (10 Slot) Chassis Power Supply" 
PID: DS-CAC97-3KW,  VID: V01 ,  SN: DTM164602ZP

NAME: "Slot 41", DESCR: "SAN384C-6 (10 Slot) Chassis Fan Module" 
PID: DS-C9710-FAN,  VID: V00 ,  SN: JAF1647ADCE

NAME: "Slot 42", DESCR: "SAN384C-6 (10 Slot) Chassis Fan Module" 
PID: DS-C9710-FAN,  VID: V00 ,  SN: JAF1647ADCN

NAME: "Slot 43", DESCR: "SAN384C-6 (10 Slot) Chassis Fan Module" 
PID: DS-C9710-FAN,  VID: V00 ,  SN: JAF1647ACHH
The following sample output is from the show interface brief command on the Supervisor-4 Module.
switch# show interface brief
---------------------------------------------------------------------------------------
Interface Vsan  Admin   Admin  Status        SFP   Oper   Oper    Port Logical   Type	
                Mode    Trunk                      Mode   Speed   Channel 
                        Mode                             (Gbps)
---------------------------------------------------------------------------------------
fc1/1      1    E      on      trunking      swl   TE      16       1           core
fc1/2      1    E      on      trunking      swl   TE      16       1           core
fc1/3      1    E      on      trunking      swl   TE      16       1           core
fc1/4      1    E      on      trunking      swl   TE      16       1           core
fc1/5      1    E      on      trunking      swl   TE      16       1           core
fc1/6      1    E      on      notConnected  swl   --      --       --          --
fc1/7      20   auto   off     up            swl   F       8        --          edge
fc1/8      20   F      off     up            swl   F       16       --          edge
The following sample output is from the show interface status command on the Supervisor-4 Module.
switch# show interface status
fc1/1 is trunking
   Hardware is Fibre Channel, SFP is short wave laser w/o OFC (SN) 
   Port WWN is 20:01:54:7f:ee:eb:7a:00
   Peer port WWN is 20:41:00:2a:6a:5b:da:80 
   Admin port mode is E, trunk mode is on 
   snmp link state traps are enabled
   Port mode is TE
   Port vsan is 1
   Admin Speed is auto max 32 Gbps 
   Operating Speed is 16 Gbps  
   Rate mode is dedicated
   Port flow-control is R_RDY

   Transmit B2B Credit is 500 
   Receive B2B Credit is 500
   B2B State Change: Admin(on), Oper(up), Negotiated Value(14) 
   Receive data field Size is 2112
   Beacon is turned off 
   Logical type is core 
   Belongs to port-channel1
   Trunk vsans (admin allowed and active) (1,20-25,102) 
   Trunk vsans (up)	(1,20)
   Trunk vsans (isolated)	(21-25,102)
   Trunk vsans (initializing)	()
   5 minutes input rate 1568 bits/sec,196 bytes/sec, 2 frames/sec
   5 minutes output rate 576 bits/sec,72 bytes/sec, 5 frames/sec 
   5716 frames input,355028 bytes
       0 discards,0 errors
       0 invalid CRC/FCS,0 unknown class
       0 too long,0 too short
   10924 frames output,971836 bytes
       0 discards,0 errors
     0 input OLS,0  LRR,0 NOS,0 loop inits
     0 output OLS,0 LRR, 0 NOS, 0 loop inits
   500 receive B2B credit remaining
   500 transmit B2B credit remaining
   500 low priority transmit B2B credit remaining 
   Last clearing of "show interface" counters : n
The following sample output is from the show system redundancy status command on the Supervisor-4 Module.
switch# show system redundancy status

Redundancy mode
---------------
administrative:    HA 
operational:       HA

This supervisor (sup-6)
-----------------------
Redundancy state:      Active 
Supervisor state:      Active
Internal state:        Active with HA standby

Other supervisor (sup-5)
------------------------
Redundancy state:     Standby 
Supervisor state:     HA standby
Internal state:       HA standby