Installing an OSFP Transceiver
The device supports only transceivers that are qualified for Brocade devices.
If you use an unqualified transceiver, the switchshow command output shows the
port in a Mod_Inv state. The operating system also logs the issue in the system error log.
To insert an OSFP transceiver and cable, complete the following steps.
- Push the transceiver into the port using the pull tab. Transceivers are keyed so that they can be inserted only with the correct orientation. If a transceiver does not slide in easily, ensure that it is correctly oriented. Push the correctly oriented transceiver into the port until it is firmly seated and the latching mechanism clicks.Note: Always use the transceiver pull tab to insert or remove the OSFP transceivers, as the transceiver might be hot.
Figure 1. Installing an OSFP Transceiver into an OSFP Port .jpeg)
1 Pull tab 2 OSFP transceiver - Position the cable so that the key (the ridge on one side of the cable connector) is aligned
with the slot in the transceiver. Insert the cable into the transceiver until the latching mechanism
clicks.
The port LED displays steady amber until both ends of the cable are inserted and the link is established. When the link is fully established, the LED displays a steady green.
Note: Cables are keyed so that they can be inserted in only one way. If a cable does not slide in easily, ensure that it is correctly oriented. Do not insert any unsupported cable intended for another type of transceiver into a regular OSFP transceiver. You may damage the cable as well as the transceiver. - Organize the cables to avoid covering LEDs and air vents. See Cable Management.