Verifying Correct Operation
Perform the following steps to verify correct operation of the device.
- Check the LEDs of all power supplies, fans, and blades to verify that all are functional.
- Log on to the device using one of the following methods:
- A serial console connection to the active CP blade. The active CP is indicated by an illuminated blue LED on the blade front panel.
- A SSH session using the chassis management IP address.
- Log on to the device using
adminas your password. If you have not changed the default password, usepassword. - Verify the correct operation of the device by entering the following commands. Copy the output to a file to save the information.
The following table lists the commands to use to verify the correct operation.
| Command | Description |
errDump |
Displays any errors. |
fabricShow |
Displays information about the device operation in the fabric and general information about the fabric. |
fanShow |
Displays fans status and information. |
historyShow |
Displays the device history. |
psShow |
Displays power supply status and information. |
slotShow |
Displays the current status of each slot in the device. |
slotshow -m |
Displays blades (with model numbers) detected in each slot. |
slotshow -p |
Displays power consumption data and enabled status for installed blades. |
switchShow |
Displays switch status and information. |
tempShow |
Displays temperature status and information. |