Troubleshooting IBM Sterling Transformation Extender installation process

If IBM Sterling Transformation Extender installation fails, verify that ports listed in the table are available on your machine.

To verify the required port availability, follow this procedure:
  1. Open the windows terminal with administrative privileges.
  2. Run the command for each of the listed ports
    powershell -command "(Get-NetTCPConnection -LocalPort <port number>).OwningProcess"
    Note: If any of the ports are occupied, command will return the owning process id.
If any of the ports are already used by some other applications, either uninstall the port owning application, or change the default port values. You can change the related port configuration parameters:
  1. During IBM Sterling Transformation Extender InstallShield installation.
  2. Post installation, you will need to reinstall IBM Sterling Transformation Extender as described in the table below.

Refer Installation prerequisites section for "Ports used by IBM Sterling Transformation Extender application" table.