Changing maps impacted in the hipaa_x12_pass_through source map

If both the ICD-9 and ICD-10 codes are required, the schemas in the hipaa_x12_pass_through source map must be replaced.

Follow this procedure for each map that is impacted in the hipaa_x12_pass_through source map.
Maps impacted Input card number and name Default type schema ICD-9 and ICD-10 schema
hipaa_x12_pass_through #1 HIPAA_X12_Inbound_Transmission hipaa_x12 hipaa_x12_icd9_icd10
hipaa_x12_pass_through #2 HIPAA_X12_Outbound_Transmission hipaa_x12 hipaa_x12_icd9_icd10
hipaa_x12_type_1 No changes are required. - -
hipaa_x12_type_2 #1 HIPAA_X12_Inbound_Transmission hipaa_x12_type_2 hipaa_x12_type_2_icd9_icd10
hipaa_x12_type_2 #2 HIPAA_X12_Outbound_Transmission hipaa_x12_type_2 hipaa_x12_type_2_icd9_icd10
  1. Open source map hipaa_x12_pass_through by using Design Server.
  2. Double-click on the executable map to select it for modification.
  3. Edit the input card that is listed to point to the appropriate *_icd9_icd10 schema instead of the default type schema.
  4. Select NO when prompted, then replace all similar schema paths in all of the maps.
  5. Edit the Output card with the same number as the input card that you modified to point to the appropriate *_icd9_icd10 schema instead of the default schema.
  6. Select NO when prompted, then replace all similar schema paths in all maps.
  7. Build the maps after all maps are updated.