Power Analysis of Independent-Samples Binomial Test: Plot

The Plot dialog provides options for controlling the plots that are output to illustrate the two and three-dimensional power estimation charts. The dialog also controls the vertical and horizontal rotation degrees for three-dimensional charts.

Two-Dimensional Plot
Provides options for controlling the two-dimensional power estimation versus charts. This setting is disabled by default.
Power estimation versus group size ratio/Power estimation versus group size
When enabled, this optional setting controls the two-dimensional power by group size ratio chart. When selected, this setting displays the chart. The additional settings are not available when multiple power values have been specified (Power estimation versus group size). The setting is disabled by default.
Plot range of group size ratio
When selected, the lower and upper bound options are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation versus total number of pairs chart. The value must be greater than .01, and cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation versus total number of pairs chart. The value must be greater than the Lower bound value and cannot be greater than 100.
Power estimation versus risk difference
When enabled, this optional setting controls the two-dimensional power by risk difference chart. The setting is disabled by default. When selected, this setting displays the chart.
Power estimation versus risk ratio
When enabled, this optional setting control the two-dimensional power by risk ratio chart. The setting is disabled by default.
Plot range of risk ratio
When selected, the lower and upper bound options are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation versus risk ratio chart. The value cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation versus risk ratio chart. The value must be greater than the Lower bound value and cannot be greater than 10.
Power estimation versus odds ratio
When enabled, this optional setting controls the two-dimensional power by odds ratio chart. The setting is disabled by default. When selected, this setting displays the chart.
Plot range of odds ratio
When selected, the lower and upper bound options are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation versus odds ratio chart. The value cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation versus odds ratio chart. The value must be greater than the Lower bound value and cannot be greater than 10.
Three-Dimensional Plot
Provides options for controlling the three-dimensional power estimation versus charts. This setting is disabled by default.
Power estimation versus proportions
When selected, this optional setting provides the following power by proportion options:
proportion of group 1 on x-axis and proportion of group 2 on y-axis
Controls the three-dimensional power by proportion of Group 1 (x -axis) and proportion of Group 2 (y-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
proportion of group 1 on y-axis and proportion of group 2 on x-axis
Controls the three-dimensional power by proportion of Group 2 (x -axis) and proportion of Group 1 (y-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
Power estimation versus group sizes
When selected, this optional setting provides the following power by group sizes options:
size of group 1 on x-axis and size of group 2 on y-axis
Controls the three-dimensional power by number of trials in Group 1 (x -axis) and number of trials in Group 2 (y-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
size of group 1 on y-axis and size of group 2 on x-axis
Controls the three-dimensional power by number of trials in Group 2 (x -axis) and number of trials in Group 1 (y-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
Plot range of size of group 1
When selected, the lower and upper bound options for the group 1 plot range are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation versus odds ratio chart. The value must be greater than or equal to 2 and cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation versus odds ratio chart. The value must be greater than the Lower bound value and cannot be greater than 2500.
Plot range of size of group 2
When selected, the lower and upper bound options for the group 2 plot range are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation versus odds ratio chart. The value must be greater than or equal to 2 and cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation versus odds ratio chart. The value must be greater than the Lower bound value and cannot be greater than 2500.
Vertical rotation
The optional setting sets the vertical rotation degrees (clockwise from the left) for the three-dimensional chart. You can use the mouse to rotate the chart vertically. The setting takes effect when the three-dimensional plot is requested. The value must be a single integer value less than or equal to 359. The default value is 10.
Horizontal rotation
The optional setting sets the horizontal rotation degrees (clockwise from the front) for the three-dimensional chart. You can use the mouse to rotate the chart horizontally. The setting takes effect when the three-dimensional plot is requested. The value must be a single integer value less than or equal to 359. The default value is 325.