Power Analysis of Univariate Linear Regression: Plot

You can control the plots that are output to illustrate the two and three-dimensional power by charts. You can also control the display of tool tips and the vertical/horizontal rotation degrees for three-dimensional charts.

Two-Dimensional Plot
Provides options for controlling the two-dimensional power estimation versus charts. The settings are disabled by default.
Power estimation versus the multiple partial correlation
When enables, this optional setting controls the two-dimensional power by multiple partial correlation coefficient chart. The setting is disabled by default. When selected, this setting displays the chart.
Power estimation versus sample size
When enabled, this optional setting controls the two-dimensional power by sample size chart. The setting is disabled by default. When selected, this setting displays the chart.
Plot range of sample size
When selected, the lower and upper bound options are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation by sample size chart. The value must be greater than or equal to 4, and cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation by sample size chart. The value must be greater than the Lower bound value and cannot be greater than 5000.
Three-Dimensional Plot
Provides options for controlling the three-dimensional power estimation versus charts, the vertical/horizontal rotation settings, and the user specified plot range of sample size. This setting is disabled by default.
Power estimation versus sample size
When enabled, this optional setting controls the three-dimensional power by sample size charts. The setting is disabled by default. When selected, this setting displays the chart.
on x-axis and the multiple partial correlation on y-axis
This optional setting controls the three-dimensional power by sample size (x-axis) and multiple partial correlation coefficient (y-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
on y-axis and the multiple partial correlation on x-axis
This optional setting controls the three-dimensional power by sample size (y-axis) and multiple partial correlation coefficient (x-axis) chart. The setting is disabled by default. When selected, this setting displays the chart.
Plot range of sample size
When selected, the lower and upper bound options are available. When no integer values are specified for the Lower bound or Upper bound fields, the default plot range is used.
Lower bound
Controls the lower bound for the two-dimensional power estimation by sample size chart. The value must be greater than or equal to 4, and cannot be greater than the Upper bound value.
Upper bound
Controls the upper bound for the two-dimensional power estimation by sample size chart. The value must be greater than the Lower bound value and cannot be greater than 5000.
Vertical rotation
The optional setting sets the vertical rotation degrees (clockwise from the left) for the three-dimensional chart. You can use the mouse to rotate the chart vertically. The setting takes effect when the three-dimensional plot is requested. The value must be a single integer value less than or equal to 359. The default value is 10.
Horizontal rotation
The optional setting sets the horizontal rotation degrees (clockwise from the front) for the three-dimensional chart. You can use the mouse to rotate the chart horizontally. The setting takes effect when the three-dimensional plot is requested. The value must be a single integer value less than or equal to 359. The default value is 325.