hsmlogsampleinterval

The hsmlogsampleinterval option specifies how often to gather file system data for the HSM log file.

You must be an authorized user to use the hsmlogsampleinterval option.

Options File

Place this option in the client system options file dsm.sys within a server stanza.

Syntax


1  HSMLOGSampleinterval interval

Parameters

interval
Specifies the number of seconds between each gathering of file system data. The range of values is 0 - 9999999 and the default value is 3600 (one hour). If 0 is specified, no file system data is gathered.