Adding storage systems
Add the storage systems that you want to monitor in IBM Spectrum® Control.
- Every 1 minute for IBM® block storage systems
- Every 5 minutes for Dell EMC Unity storage systems
- Every 5 minutes for Hitachi VSP storage systems
- Every 5 minutes for NetApp storage systems that are running ONTAP 9
- Every 5 minutes for Pure storage systems
- Every 15 minutes for other Dell EMC block storage systems.
You can add multiple storage systems at the same time, or add them one by one. To add multiple storage systems, the storage systems must be of the same type and share authentication credentials.
- To add storage systems, you must have Administrator privileges.
- When a monitored device experiences the Daylight Saving Time (DST) clock change during the fall of the year, it generates duplicate performance samples during the fall back hour. IBM Spectrum Control detects these duplicate samples and generates the error HWNPM4302E. This behavior is expected because the clock shifts back by one hour, causing the device to produce performance samples with duplicate timestamps in IBM Spectrum Control.
- When a monitored device undergoes a Daylight Saving Time (DST) change or a time zone update, additional alerts for port bandwidth utilization, high CPU utilization, or other metrics may be generated due to overlapping or missing time intervals.
| Storage system | Can add many at same time. |
|---|---|
| DS8000® | ![]() |
| Dell EMC Unity | ![]() |
| Dell EMC VMAX | |
| Dell EMC VNX | |
| Dell EMC VNXe | |
| IBM Storage FlashSystem 5000 | ![]() |
| IBM Storage FlashSystem 5100 | ![]() |
| IBM Storage FlashSystem 5200 | ![]() |
| IBM Storage FlashSystem 7200 | ![]() |
| IBM Storage FlashSystem 7300 | ![]() |
| IBM Storage FlashSystem 9100 | ![]() |
| IBM Storage FlashSystem 9200 | ![]() |
| IBM Storage FlashSystem 9500 | ![]() |
| IBM Storage FlashSystem V9000 | ![]() |
| IBM Storage FlashSystem 900 | ![]() |
| IBM FlashSystem A9000 | ![]() |
| IBM FlashSystem A9000R | ![]() |
| Hitachi VSP | ![]() |
| NetApp ONTAP 9 | ![]() |
| NetApp ONTAP 8 (7- mode) | |
| Pure | ![]() |
| IBM Storage Accelerate™ | ![]() |
| IBM Storage Scale™ (ESS and GSS) | |
| IBM Storage Virtualize™ | ![]() |
| IBM Storage Virtualize for Public Cloud | ![]() |
| SAN Volume Controller | ![]() |
| Storwize® V3500 | ![]() |
| Storwize V3700 | ![]() |
| Storwize V5000 | ![]() |
| Storwize V5000E | ![]() |
| Storwize V7000 | ![]() |
| IBMStorwize Flex System V7000 Storage Node | |
| Storwize V7000 Unified | |
| XIV® | ![]() |
| All others (managed by SMI-S providers) |
- When you add a storage system for monitoring, you must enter a user name and password that is used to connect to that storage system. In rare cases, special characters in the user name or password might not be allowed by IBM Spectrum Control. If you can't add a storage system because of restricted characters, change its credentials and try to add it again. Then, open a ticket for the character limitation so that it can be addressed in a future update.
- IBM Spectrum Control doesn't support monitoring non-IBM software-defined storage devices. However, it can monitor IBM software-defined storage devices, such as IBM SAN Volume Controller. For a list of storage devices that can be monitored, check out https://www.ibm.com/support/pages/node/6249369.
- To monitor the performance of a Storwize V7000 Unified storage system, you must add it as a block storage system.
- To monitor an IBM Storage Virtualize for Public Cloud
storage system, you must configure it for communication with IBM Spectrum
Control. For more
information, see
Configuring IBM Storage Virtualize for Public Cloud. - For a complete list of the versions of storage systems and
SMI-S providers that you can add, and the firmware levels of supported storage systems, see
IBM Spectrum Control interoperability matrix for storage systems.
Storage systems can be configured for block storage, file storage, a combination of block and file storage, or a combination of file and object storage. The method that a storage system uses for managing data determines the internal resources and object resources that are monitored.
After you add storage systems, a task is added to the list of running tasks on the page banner. If the task fails, the task is added to the list of failed tasks on the page banner. You can retry failed tasks or clear them from the list.
After the probe is run, agentless servers are updated with any new information about the host connections on the storage systems. You can review the agentless servers on the Servers page, and make any changes that are required.