Frequently Asked Questions

View answers to common questions about IBM Spectrum Control.

How do you know if your storage system is supported by IBM Spectrum Control and which SMI-S agents are supported?
To confirm whether your storage system is supported and which SMI-S agent is supported for that system, review the supported products list for the current release of IBM Spectrum Control at IBM Spectrum Control interoperability matrix for storage systems.
You encounter errors while collecting performance data on SAN Volume Controller. You fail to associate SAN Volume Controller performance data from non-configuration node with SAN Volume Controller performance data from configuration node. You encounter incomplete SAN Volume Controller performance data sample.
This issue is caused by a configuration issue with SAN Volume Controller (time zone). Reset the time zone on SAN Volume Controller by logging into the SAN Volume Controller through putty. Run this command first:
svctask settimezone -timezone 509
This forces the cluster into the Universal time zone. To get the time zone you want the cluster to be in, run this command:
svctask settimezone -timezone