HWNLM0715E There are no common fabrics that have the minimum number of required paths between the selected servers and the managed storage systems.

Explanation

In order for the SAN Planner action to proceed, there needs to be at least one common fabric between the hosts and storage subsystems. If multipath planning is specified, at least two data paths between each host and storage subsystem is required. For virtual disks, an I/O group requires two nodes to be connected to a common fabric. If only one node of the I/O group has a working connection to the fabric, then the I/O group cannot be used for path planning.

Action

Select one or more hosts and storage subsystems within the same fabric, then try the SAN Planner action again. For virtual disks, check the status of the connectivity of the nodes of the I/O groups on the SVC. Ensure both nodes of each I/O group have a working connection to the same fabrics as the selected hosts, then probe the SVC and fabrics again. Once the probes complete, try the SAN Planner action again.