Upgrading Watson Studio from Version 5.3.x to a later Version 5.3 refresh
An instance administrator can upgrade Watson Studio from Version 5.3.x to a later Version 5.3 refresh.
- Who needs to complete this task?
-
Instance administrator To upgrade Watson Studio, you must be an instance administrator. An instance administrator has permission to manage software in the following projects:
- The operators project for the instance
-
The operators for this instance of Watson Studio are installed in the operators project. In the upgrade commands, the
${PROJECT_CPD_INST_OPERATORS}environment variable refers to the operators project. - The operands project for the instance
-
The custom resources for the control plane and Watson Studio are installed in the operands project. In the upgrade commands, the
${PROJECT_CPD_INST_OPERANDS}environment variable refers to the operands project.
- When do you need to complete this task?
-
Review the following options to determine whether you need to complete this task:
- If you want to upgrade the IBM Software Hub control plane and one or more services at the same time, follow the process in Upgrading an instance of IBM Software Hub instead.
- If you didn't upgrade Watson
Studio when you upgraded the IBM Software
Hub
control plane, complete this task to upgrade Watson
Studio.
Repeat as needed If you are responsible for multiple instances of IBM Software Hub, you can repeat this task to upgrade more instances of Watson Studio on the cluster.
Information you need to complete this task
Review the following information before you upgrade Watson Studio:
- Version requirements
-
All the components that are associated with an instance of IBM Software Hub must be installed at the same release. For example, if the IBM Software Hub control plane is at Version 5.3.1, you must upgrade Watson Studio to Version 5.3.1.
- Environment variables
- The commands in this task use environment variables so that you can run the commands exactly as
written.
- If you don't have the script that defines the environment variables, see Setting up installation environment variables.
- To use the environment variables from the script, you must source the environment variables
before you run the commands in this task. For example,
run:
source ./cpd_vars.sh
- Common core services
- Watson
Studio requires the IBM Software
Hub
common core services.
If the common core services are not at the correct version in the operands project for the instance, the common core services are automatically upgraded when you upgrade Watson Studio. The common core services upgrade increases the amount of time the upgrade takes to complete.
Before you begin
This task assumes that the following prerequisites are met:
- System requirements
- This task assumes that the cluster meets the minimum requirements for Watson
Studio.
Where to find more information If this task is not complete, see System requirements. - Workstation
- This task assumes that the workstation from which you will run the upgrade is set up as a client
workstation and has the following command-line interfaces:
- IBM Software
Hub CLI:
cpd-cli - OpenShift® CLI:
oc - Helm CLI:
oc
Where to find more information If this task is not complete, see Updating client workstations. - IBM Software
Hub CLI:
- Control plane
- This task assumes that the IBM Software
Hub
control plane is upgraded.
Where to find more information If this task is not complete, see Upgrading an instance of IBM Software Hub. - Private container registry
- If your environment uses a private container registry (for example, your cluster is air-gapped),
this task assumes that the following tasks are complete:
- The Watson
Studio software images are mirrored to the private container
registry.
Where to find more information If this task is not complete, see Mirroring images to a private container registry. - The
cpd-cliis configured to pull theolm-utils-v4image from the private container registry.Where to find more information If this task is not complete, see Pulling the olm-utils-v4 image from the private container registry.
- The Watson
Studio software images are mirrored to the private container
registry.
- Cluster-scoped resources
- This task assumes that the cluster-scoped resources, such as custom resource definitions,
cluster roles, and cluster role bindings, were updated.
Where to find more information If this task is not complete, see Updating the cluster-scoped resources for the platform and services.
Procedure
Complete the following tasks to upgrade Watson Studio:
Upgrading the service
To upgrade Watson Studio:
-
Log the
cpd-cliin to the Red Hat® OpenShift Container Platform cluster:${CPDM_OC_LOGIN}Remember:CPDM_OC_LOGINis an alias for thecpd-cli manage login-to-ocpcommand. - Update the operator and custom
resource for Watson
Studio.
cpd-cli manage install-components \ --license_acceptance=true \ --components=ws \ --release=${VERSION} \ --patch_id=${PATCH_ID} \ --operator_ns=${PROJECT_CPD_INST_OPERATORS} \ --instance_ns=${PROJECT_CPD_INST_OPERANDS} \ --image_pull_prefix=${IMAGE_PULL_PREFIX} \ --image_pull_secret=${IMAGE_PULL_SECRET} \ --upgrade=true
Validating the upgrade
install-components command
returns:[SUCCESS]... The install-components command ran successfully
If you want to confirm that the custom resource status is
Completed, you can run the cpd-cli
manage
get-cr-status command:
cpd-cli manage get-cr-status \
--cpd_instance_ns=${PROJECT_CPD_INST_OPERANDS} \
--components=ws
What to do next
- Upgrade all installed Watson Studio Runtimes. For details, see Watson Studio Runtimes for Watson Studio.
After you complete the preceding steps, Watson Studio is ready to use. For details, see Getting started with Watson Studio.