The total transaction timeout value is set to 600 seconds by default. Depending on the
setting, some long running IBM® Security Guardium® Key Lifecycle Manager operations
might timeout.
About this task
Long
running IBM Security Guardium Key Lifecycle Manager operations
might timeout with an error message like this example:[10/21/08 14:28:41:693 CDT] 00000020 TimeoutManage I
WTRN0006W: Transaction 00000110001 has timed out after xxx seconds.
To
configure the transaction timeout interval to a larger value, take
these steps:
Procedure
-
Stop the server.
- Windows
systems:
In the WAS_HOME\bin
directory,
type:
stopServer.bat
- AIX® and Linux®
systems:
In the WAS_HOME/bin
directory, type:
./server.sh stop server1
-
Edit this file:
..\profiles\KLMProfile\config\cells\SKLMCell\nodes\SKLMNode\
servers\server1\server.xml
-
Change the propogatedOrBMTTranLifetimeTimeout parameter
to a larger value.
-
Save the file.
-
Start the server.
- Windows systems:
In the WAS_HOME\bin
directory,
type:
startServer.bat
- AIX and Linux
systems:
In the WAS_HOME/bin
directory, type:
./startServer.sh
Table 1. Topic change
log
Date |
Change description |
06 January 2023 |
Corrected the server start and stop commands. |
20 April 2022 |
Corrected the commands for stopping WebSphere® Liberty on AIX or Linux. |
10 Sept 2021 |
Initial version. |