Removing and replacing the power supply unit
Remove the existing power supply unit of the server and replace it with a new one.
Before you begin
- Prerequisites for removing the power supply unit
-
- The server is shipped with two power supply by default. In this case, the power supply is hot pluggable and redundant.
- Ensure that you power off the server and disconnect all the power cords and network cables before you remove the power supply unit.
- Ensure that you put the node into maintenance mode. For more about node maintenance, see Administering the node.
- Ensure that you install an additional hot-swap power supply to support redundancy.
- Ensure that you wear an ESD wrist strap when you remove the power supply unit.
- Ensure that you handle the component carefully and include more than one qualified person to perform the task if the component weight is more than 18 kg (40 lb).
- Prerequisites for replacing the power supply unit
-
- The server is shipped with only one power supply by default. In this case, the power supply is non-hot swap.
- Ensure that you power off the server and disconnect all the power cords and network cables before you replace the power supply unit.
- Ensure that you put the node into maintenance mode. For more about node maintenance, see Administering the node.
- Ensure that you install an additional hot-swap power supply to support redundancy.
- Ensure that you wear an ESD wrist strap when you replace the power supply unit.
- Ensure that you handle the component carefully and include more than one qualified person to perform the task if the component weight is more than 18 kg (40 lb).
About this task
Remove and replace the power supply unit in the specified order. The following table lists the
MTMs of all servers:
Marketing name | Component | Machine type | Model | ECCN | HTS |
---|---|---|---|---|---|
IBM Storage Fusion HCI System Compute/Storage Server | Compute Storage Node SR645 | 9155 | C01 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System Compute/Storage Server | Compute Storage Node SR645 | 9155 | C05 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System Compute Server | Compute Storage Node SR645 Zero Drives | 9155 | C00 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System Compute Server | Compute Storage Node SR645 Zero Drives | 9155 | C04 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System 100GbE High-Speed Switch | NVIDIA 9155-S01 Fabric High-Speed Switch | 9155 | S01 | 5A991.b.4.a | 8517620020 |
IBM Storage Fusion HCI System 1GbE Switch | NVIDIA AS4610 Switch | 9155 | S02 | 5A991.b.4.a | 8517620020 |
IBM Storage Fusion HCI System AFM Server | AFM Server SR630 | 9155 | F01 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System GPU Server | GPU Server SR665 | 9155 | G01 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System GPU Server | GPU Server SR650 V3 | 9155 | G02 | 5A992.c | 8471500150 |
IBM Storage Fusion HCI System Rack | Constellation Rack | 9155 | R42 | EAR99 | 8473305100 |
IBM Storage Fusion HCI System KVM | Rackmount Console Kit | 9155 | TF5 | 5A992 | 8537109170 |
Procedure
What to do next
- Install a power supply filler or a new power supply to cover the slot.
- If you are instructed to return an old hot-swap power supply, follow all packaging instructions and use any packaging materials provided.
- If the server is turned off, turn on the server. Ensure that both the power input LED and the power output LED on the power supply are lit, indicating that the power supply is operating properly.