Release Notes SevOne SDN Collector 8.0.0 Monitoring Solution
Below please find the Release Notes for SevOne SDN Collector 8.0.0 Monitoring Solution (Release Date: July 24, 2025). Please contact your Technical Account Manager (if applicable) or Systems Engineering Team or IBM SevOne Support Team to discuss and plan the installation. Thank you for being a customer.
Resources & Requirements
Compatibility Matrix
- T – Tested & S – Supported
| SevOne NMS | REST API | Service-Oriented Architecture (SOA) | SevOne Data Insight | Collector Cisco ACI |
|---|---|---|---|---|
| 8.0.0 (T & S) | 2.1.47 | >= 8.0.0 | 8.0 (T & S) |
APIC- 6.0 (T & S) APIC - 5.x (T & S) ACI MSO - v3.x (T & S) |
SevOne Data Insight
- Please refer to Release Notes SevOne Data Insight for details.
SevOne NMS
-
An administrator-level account in SevOne NMS.
-
User name and password for the administrator-level account.
-
IP address of the PAS.
-
20k (vPAS_20K) appliance (minimum requirement).
Collector Cisco ACI
-
APIC 5.x
-
ACI Multi-Site Orchestrator (MSO) v3.x
-
An administrator-level account in the APIC and MSM. This is necessary in order for the SDN ACI Collector to communicate with the APIC REST API.
-
User name and password for the administrator-level account.
-
IP address of the APIC / MSM.
Recommendation
If the SEVONE_API_PASSWORD changes, the collection will be stopped unless the settings.env and multi_site_config.json files are updated with the new password. The new configure option in the launch script provides the user with a command line interface to do the same.
- Do not rename devices or objects created by the Solution. This can potentially break data collection. Please use alternative name fields if a custom name is required.
- Do not enable automatic DNS name resolution in SevOne NMS cluster. If enabled, it allows NMS to rename the devices based on the DNS record and break the data collection.
Useful Guides
From IBM's Documentation Portal (https://www.ibm.com/docs/en/sevone-npm) , please refer to SDN / SevOne Data Insight guides for this release for details.
Formula: TCAM Utilization (%) = ( (polUsageCum − polUsageBase) / polUsageCapCum ) × 100
What it means: TCAM (Ternary Content Addressable Memory) tracks how much policy space is being used on a leaf switch. It helps ensure the switch does not run out of space for policies.
- polUsageCum: Current number of policies used
- polUsageBase: Baseline policy count
- polUsageCapCum: Max policy capacity
New Features / Enhancements
New enhancements in SDN:
- Certificate-based authentication: SDN now supports certification-based authentication.
- ACI configuration simplification: Cisco ACI configuration is now simplified to accelerate Time to Value.
Resolved Issues
| Key | Resolved Issues |
|---|---|
| S1NPM-113801 | Platform: In certificate-based authentication, the destination peer must have the appropriate certificate to resume data collection when a device is moved from a source peer. |
| S1NPM-114402 | Platform: After upgrading SevOne NMS 7.0.0 to SevOne NMS 7.1.x and above, the FaultStreamingAgent is now operating as expected, this is confirmed by the presence of both Run agent start agent=FaultStreamingAgent and Run agent done in the logs. The indicator values are now correctly displayed in SevOne NMS. This issue has been resolved. |
| S1NPM-114838 | Addressed CVE-2025-22868. |
| S1NPM-115498 | Platform: The logrotate configuration now adheres to the following behavior.
|
| S1NPM-115679 | Platform: In SevOne NMS versions 7.0.x, 7.1.x, and 7.2.x changes made to default.yaml are now applied to site.yaml automatically. By migrating configuration to advance-site.yaml, now ensures automatic update of changes without manual intervention. This issue has been resolved. |
5 issues
Known Issues
This section lists issues that SevOne is aware of in SevOne SDN Collector 8.0.0 Monitoring Solution. Most of these issues were discovered during quality assurance testing and are published here to provide you with information that may be relevant when you plan your update. This list does not include feature requests or low impact issues that do not affect functionality. If you have questions, comments, or concerns, please contact us.
- ACI Switch Capacity widget has a few pre-set max values. For example, rather than using the APIC API max values, VRF's max value is 800 (400 for NorthStar model) and EPG's max value is 3960.
| Key | Known Issues |
|---|---|
|
S1NPM-116660 |
Platform: Alerts are currently generated even when the associated device is not found in the SevOne NMS database. This behavior can result in unnecessary alert noise, particularly when a device has been intentionally removed or has not yet completed provisioning. |
|
S1NPM-116910 |
Platform: Device type name fails to update following an upgrade. |
|
S1NPM-116925 |
Platform: After adding SDN device to SevOne NMS version 8.0 and configuring the data source in SevOne Data Insight, the ACI SDN Capacity widget in SevOne Data Insight displays incorrect data, showing 0% values for Hypervisor, Virtual Machines, and Virtualization. |
|
S1NPM-116981 |
Platform: After adding an SDN device to SevOne NMS version 8.0.0 and configuring the data source in SevOne Data Insight, the Cisco ACI Fabric report does not display any data when the Mapping or Topology tab is selected. |
|
S1NPM-116998 |
Platform: After adding an SDN device to SevOne NMS version 8.0.0 and configuring the data source in SevOne Data Insight, the Create Report page in SevOne Data Insight does not display data when the SDN Mapping widget and SDN Logical Topology widget are added. |
|
S1NPM-117039 |
Platform: In a fresh installation of SevOne NMS version 7.2.0, the Device Type Membership tab does not display device-related details for both the SC CISCO ACI HYPERVISOR and SC CISCO ACI VM device types. Furthermore, after upgrading SevOne NMS from version 7.2.0 to 8.0.0, the Device Type Membership tab does not display device-related details for the SC CISCO ACI VM device type. |
|
S1NPM-117040 |
Platform: After upgrading SevOne NMS from version 7.2 to 8.0.0, some devices are not displayed on the Device Types page. |
|
S1NPM-117089 |
Platform: After adding SDN device to SevOne NMS version 8.0 and configuring the data source in SevOne Data Insight, the Cisco ACI Fabric Virtualization OOTB report does not display data in Data Insight. |
|
S1NPM-117098 |
Platform: After adding an SDN device to SevOne NMS version 8.0 and configuring the data source in SevOne Data Insight, data such as Ingress, Egress, and other traffic metrics are not displayed in some ACI traffic related widgets within the SDN OOTB reports. |
|
S1NPM-117131 |
Platform: The message currently displayed under the Comparison Operation section of the trigger condition for the SDN policy siteN::SDN::SelfmonAvailability incorrectly shows a percentage. However, it should reflect the elapsed time, in seconds, since the most recent data point. Example, the correct message should read as 7200 seconds since newest data point. |
|
S1NPM-117654 |
The SDN Collector generates warning messages for non-SDN devices that are not present in the SDN cache. This issue affects logging only and does not impact device discovery, data collection, or device updates.This is not an expected behavior. |
|
S1NPM-119243 |
Platform: WebSocket subscription failures prevent the Fault Streaming Agent from receiving Cisco ACI fault data The |
|
S1NPM-121365 |
A defect in the Cisco ACI SDN collector may cause runtime panics during hypervisor and VM topology discovery when APIC returns malformed or unexpected |
13 issues