Release Notes SevOne Data Insight 6.6.4

Below please find the Release Notes for SevOne Data Insight 6.6.4. Please contact your Technical Account Manager (if applicable) or Systems Engineering Team or Support Team to discuss and plan the installation. Thank you for being a customer.

Guides & Release Notes

From IBM's Documentation Portal (https://www.ibm.com/docs/en/sevone-npm), please refer to SevOne Data Insight guides and release notes under IBM SevOne Network Performance Management version 6.6 for details.

Release Notes SevOne Data Insight 6.6.0 contains the resources and other requirements, deployment recommendations, and other details that apply to SevOne Data Insight 6.6.x release.

For a list of all issues resolved in SevOne Data Insight 6.6.x, please refer to each 6.6.x release notes for details.

Browser Requirements

Minimum Resolution: 1200x768 Browsers:

  • Modern, standards-compliant browser
  • JavaScript enabled
  • Pop-up blocker disabled for hostname/IP

The following browsers are supported in the current versions of SevOne. SevOne recommends use of the latest version of your preferred (supported) browser.

Browser SevOne NMS 5.7, SevOne NMS 6.x
Vendor Family Version
Google Chrome >=100 Tested, Supported, & Recommended
Mozilla Firefox >=100 Tested & Supported
Microsoft Edge >=100 Supported
(with limited testing performed)

Tested = Complete UI regression testing completed prior to release of updates.
Supported = Developer-led testing and resolution of any customer reported defects. No complete UI regression test is performed.

Resolved Issues

In addition to the issue(s) mentioned below, please refer to each SevOne Data Insight 6.6.x release notes prior to this release for the list of all issues resolved.
When performing an upgrade to SevOne Data Insight 6.6.4, signature tools must be on the latest version. For example, v2.0.1.

CVEs

SDI-15061: The following CVEs (for frontend / backend) have been addressed.

CVEs URL
CVE-2023-38545 https://www.cve.org/CVERecord?id=CVE-2023-38545
CVE-2023-45133 https://www.cve.org/CVERecord?id=CVE-2023-45133

Build files required

File Type File Name
CHECKSUM sdi-v6.6.4-build.8.tgz.sha256.txt
TAR sdi-v6.6.4-build.8.tgz

Known Issues

This section lists issues that SevOne is aware of in the Data Insight 6.6.x release. Most of these issues were discovered during quality assurance testing and are published here to provide you with information that may be relevant when you plan your update. This list does not include feature requests or low impact issues that do not affect functionality. If you have questions, comments, or concerns, please contact us.

FYI
Due to the migration from Id to Name-based resources, if the user changes the device name in SevOne NMS, any report that had variables that were statically configure with that device name will not work. The same is true for objects that change the name as well.
  • If a SevOne Data Insight 2.2.x report is bookmarked on your browser, you will need to re-select the report variable selections and update the bookmark. Otherwise, it will not work with SevOne Data Insight 3.0 or higher.

  • Flow Widget: SevOne NMS requestd may take longer than expected to complete the report. Due to this, it is possible that the report may timeout after 15 minutes.

    This happens when a lot of resources are selected for example, All Device Groups, aggregation is set to be very granular, and greater than a month's worth of data (4 weeks+) is being requested.
  • Report Linking only applies to report variables of the same type. For example, clicking on a device will only send a Device to device report variables. However, clicking on a Device will not affect a Flow Interface report variable.

  • Administer > Teams

    • When a user is added to a new team, you need to logout and login for the change to take effect.
    • For team membership, even if multiple datasources are added to a team, only users with the proper roleID of the authorization source will be available to the team. Teams cannot have members defined in multiple datasources.
Key Known Issues
SDI-13853 Alert Details Widget / Alert Summary Widget: When no resources are selected and from Linking tab, you have selected values for Clicking on report linking and have added report variable. Once the report variable has been applied and you click on linking value, widget returns an error.
Workaround: When creating the Alert Details / Alert Summary widget, select the required resources.
SDI-13909 Performance Metrics Widget: From Analyze tab, when field Enable downsampling is enabled and from Charts tab, visualization Line, Area > Stack is enabled, the graphs are misleading for the newly added polling device objects.
Workaround: From Analyze tab, disable field Enable downsampling for stacked line to display properly.
SDI-14140 Devices: Refreshing logout token on Device Manager page results in an authentication error and logs you out.

3 issue