1092 The temperature soft or hard shutdown threshold of the 2072 has been exceeded. The 2072 has automatically powered off.
Explanation
The temperature soft or hard shutdown threshold of the 2072 has been exceeded. The 2072 has automatically powered off.
User response
- Ensure that the operating environment meets specifications.
- Ensure that the airflow is not obstructed.
- Ensure that the fans are operational.
- Perform the light path diagnostic procedures from the event log menu in the GUI.
- Check node status. If all nodes show a status of
online
, mark the error that you have just repaired asfixed
. If any nodes do not show a status ofonline
, start the fix procedure from the event log menu in the GUI. If you return to this step, contact your support center to resolve the problem. - Run the fix procedure from the event log menu in the GUI.
Possible Cause-FRUs or other:
2072 - Node Canister (100%)
- The FRU that is indicated by the Light path diagnostics (25%)
- System board (5%)
Other:
System environment or airflow blockage (70%)