712 A SAS adapter has a PCI error.
Explanation
A SAS adapter has a PCI error. On Storwize® V5000, Storwize V5000E, and FlashSystem 5000, the adapter is on the node canister system board.
Data:
- Location is a number indicates the adapter location. Location 0 indicates that the adapter is integrated into the system board is being reported. Other locations indicate an adapter slot. See the node description for the definition of the adapter slot locations.
User response
- If possible, use the management GUI to run the suggested actions for the associated service error code.
- Use the procedures to restart (physically remove and reseat) a node canister.
- If location 0 is identified, because the adapter is on the system board, replace the node canister by using the remove and replace procedures.
- If a location other than 0 is identified, use the remove and replace procedures to replace the adapter. If this procedure does not fix the problem, replace the node canister (system board in 2145-DH8 and 2145-SV1).
Possible Cause-FRUs or other cause:
- High-speed SAS adapter
- Node canister (system board in 2145-DH8 and 2145-SV1)