702 A Fibre Channel adapter has a PCI error.

Explanation

A Fibre Channel adapter has a PCI error.

This node error does not, in itself, stop the node or node canister from becoming active in the system. However, the Fibre Channel network might be being used to communicate between the nodes or node canisters in a clustered system. Therefore, it is possible that this node error indicates the reason why the critical node error 550 A cluster cannot be formed because of a lack of cluster resources is reported on the node or node canister.

Data:

  • Location is a number that indicates the adapter location. The location indicates an adapter slot; see the node or node canister description for the definition of the adapter slot locations.

User response

  1. If possible, use the management GUI to run the suggested actions for the associated service error code.
  2. Use the procedures to restart (physically remove and reseat) a node canister.
  3. Use the remove and replace procedures to replace the adapter. If this procedure does not fix the problem, then replace the node canister (system board in 2145-DH8 and 2145-SV1).

Possible Cause-FRUs or other cause:

  • Fibre Channel adapter
  • Node canister (system board on 2145-DH8 or 2145-SV1)