2035 Drive has disabled protection information support.

Explanation

An array has been interrupted in the process of establishing data integrity protection information on or more of its members by initial writes or rebuild writes.

In order to ensure the array is usable, the system has turned off hardware data protection for the member drive.

User response

If many or all the member drives in an array have logged this error, and sufficient storage exists in the pool to migrate the allocated extents, then the simplest strategy is to delete the array and recreate it once the drive service action has been accomplished.

If a small number of drives are affected then it is simplest to remove these drives from the array and service them individually. This option is not possible if the array is currently syncing post recovery.