1043 Enclosure VPD is Unavailable
Explanation
This error occurs when there is a problem with a node or node canister and the enclosure identity cannot be read.User response
Complete the following steps to troubleshoot the issue:
- Check any errors that are reported on the other node in the enclosure (the partner node).
- If the partner node is reporting the same error, follow the hardware remove and replace procedure to replace the enclosure midplane.
- If the partner node is not reporting the same error, follow the hardware remove and replace procedure to replace the node or node canister that is reporting the error.
Note: If a newly installed system reports the error on both nodes, the data that must be
written to the enclosure is not available. Contact IBM® Support Center for the worldwide node names
(WWNNs) to use.
Remember: Review the output of the
lsservicenodes command for a list of all the nodes that can be serviced by using
the service assistant CLI.
Possible Cause—FRUs or other:
- Node canister (50%)
- Enclosure midplane (50%)