Problem: SAS cabling not valid

This topic provides information to be aware of if you receive errors that indicate the SAS cabling is not valid.

Check the following items:
  • Do not connect a SAS cable between a port on a top canister and a port on a bottom canister.
  • In any enclosure, the same ports must be used on both canisters.
  • Do not connect a SAS cable between ports in the same enclosure.
  • In each enclosure, where a cable connects from SAS port 1 of the top canister to another enclosure, a cable must also connect from SAS port 1 of the bottom canister to the other enclosure. Similarly, where a cable connects from SAS port 2 of the top canister to another enclosure, a cable must also connect from SAS port 2 of the bottom canister to the other enclosure.
  • For cables connected between expansion enclosures, one end is connected to port 1 while the other end is connected to port 2.
  • For cables that are connected between a control enclosure and expansion enclosures, port 1 must be used on the expansion enclosures.
  • The last enclosure in a chain must not have cables in port 2 of the top canister, nor port 2 of the bottom canister.
  • Ensure that each SAS cable is fully inserted.