lsenclosurefanmodule

Use the lsenclosurefanmodule command to report the status of each fan module and the contained fans in an enclosure.

Syntax

Read syntax diagramSkip visual syntax diagram lsenclosurefanmodule -fanmodulefanmodule_idenclosure_id

Parameters

-delim delimiter
(Optional) Specify a delimiter to separate data in the output.
-nohdr
(Optional) Suppress the headings in the output.
-fanmodule fanmodule_id
(Optional) Specifies the ID of the fan module for which data is displayed. The possible values are 1 or 2, and any other value returns no output.
enclosure_id
(Optional) Specifies the ID of the enclosure for which data is displayed.

Description

The command reports status for fan modules and the contained fans in an enclosure.
This table provides the possible values that are applicable to the attributes that are displayed as data in the output views.
Table 1. lsenclosurefanmodule attribute values
Attribute Value
enclosure_id Indicates the enclosure ID of the enclosure that contains the fan module.
fan_module_id Indicates the fan module ID of the fan module that is in the enclosure. The possible values are 1 or 2.
status Indicates the combined status of the fan module and any contained fans. The values are:
  • online
  • offline
  • degraded
error_sequence_number Indicates the event log sequence number of the current event that is logged against the fan module. It is blank if there is no current event.
FRU_part_number Indicates the part number of the fan module.
FRU_identity Indicates the FRU identity of the fan module.
fault_LED Indicates the status of the fault light-emitting diode (LED) on the fan module:
  • on, which indicates that the LED is on
  • off, which indicates that the LED is off
  • unknown, which indicates that the LED status is unknown