Learn about the possible problems and service actions that you can perform to resolve a
storage device problem.
About this task
Table 1. Storage device problems and service actions
| Problem |
Service action |
| System is unable to find more than one storage device |
- If the system was recently installed, moved, serviced, or upgraded, verify that the device is
seated and installed properly.
- Verify that the device is compatible with your system.
- Verify that all internal cables are properly seated and are not physically damaged.
- Verify that the most recent firmware is installed on the system, or install the most recent
firmware if it is not already installed.
- If the devices are part of a RAID configuration, ensure that the device has been enabled and is
part of an array.
-
Replace the cable that connects the disk drive backplane to the system backplane.
|
| System unable to find a storage device |
- If the system was recently installed, moved, serviced, or upgraded, verify that the device is
seated and installed properly.
- Verify that the device is compatible with your system.
- Verify that all internal cables are properly seated and are not physically damaged.
- Verify that the most recent firmware is installed on the system, or install the most recent
firmware if it is not already installed.
- If the device is part of a RAID configuration, ensure that the device has been enabled and is
part of an array.
- Install the device in an open or free slot. If the device is able to be found replace the
component with the failing connector.
- Replace the storage device.
- Replace any applicable attached cable.
|
| More than one storage device suddenly stops working |
- If the system was recently installed, moved, serviced, or upgraded, verify that the device is
seated and installed properly.
- Check the system logs to verify whether the system detected a problem.
- Replace
the cable that connects the disk drive backplane to the system backplane.
|
| One storage device suddenly stops working |
- Verify that all internal cables are properly seated and are not physically damaged.
- Check the system logs to verify whether the system detected a problem.
- Replace the drive.
- Replace the system backplane.
- Replace the cable.
|
| Other problems |
Check the messages and resolve any other problems that were detected. Then, test the drive
again. If the drive continues not to function, refer to the documentation for the drive. |