subscribe iconSubscribe to this information
POWER7 information

MAP 4149

Use this MAP to resolve the following problem: Incomplete multipath connection between controller and remote controller (SRN nnnn - 9075)

The possible cause is a failure in the embedded SAS fabric. Use the following table to determine the service action to perform.

Table 1. Service actions for a failure in the embedded SAS fabric
Location of device or devices Service action
8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD Replace the following FRUs, one at a time, in the order shown until the problem is resolved. See Part locations and location codes to determine the location, part number, and replacement procedure to use for each FRU.
  1. Small form factor SAS disk drive backplane with embedded SAS adapters at location Un-P2-C9.
  2. I/O backplane at location Un-P2.
Disk expansion unit attached to an 8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD Replace the cables to the disk expansion unit. If that does not resolve the problem, see the service information for the disk expansion unit for additional FRUs to replace.


Send feedback Rate this page