| 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C,
or 8205-E6D |
- FC 5631 (Split disks enablement adapter)
|
- SSD and HDD cannot be mixed in the same RAID array or mirroring
group.
- SSDs and HDDs can be connected to the 5886 from the external SAS
port.
- 5631 can be used to split disks
|
| 5802 and 5877 |
FC 5903 (PCIe 380 MB Cache Dual x4 3 Gb SAS
RAID Adapter) |
- SSD and HDD cannot be mixed on a pair of 5903 adapters.
- A maximum of 9 SSDs are supported on a pair of 5903 adapters.
|
| 5886 |
- FC 5904 (PCI-X DDR 1.5 GB Cache SAS RAID Adapter)
- FC 5906 and FC 5908 (PCI-X DDR 1.5 GB Cache SAS RAID Adapter)
- FC 5903 (PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter)
|
- SSDs and HDDs can be mixed in this drive enclosure.
- A maximum of 24 drives are supported in this enclosure.
- SSDs and HDDs can be attached to the SAS Controller PCI or PCI-X
adapters. Also, can be attached to the embedded SAS controller in
a system with an embedded SAS port.
|
| 5887 disk
drive enclosure |
- FC 5805 (PCIe 380 MB Cache Dual - x4 3 Gb SAS RAID Adapter)
- FC 5901 (PCIe Dual x4 SAS Adapter)
- FC 5908 (PCI-X DDR 1.5 GB Cache SAS RAID Adapter)
- FC ESA1 (PCIe2 RAID SAS Adapter Dual-port 6 Gb)
- FC ESA1 (PCIe2 LP RAID SAS Adapter Dual-port 6 Gb)
- PCIe2 (3.1 GB Cache RAID SAS Enclosure 6 Gb x8)
|
- A maximum of 24 drives are supported in this enclosure.
- The EXP24S can be configured as one set of 24 bays (mode 1), two
sets of 12 bays (mode 2), or four sets of 6 bays (mode 4).
- The EXP24S serial-attached SCSI (SAS) ports are attached to SAS
controllers, which can be a SAS Peripheral Component Interconnect-X
(PCI-X) adapter, PCI Express (PCIe) adapter, or a pair of adapters.
The EXP24S can also be attached to an embedded SAS controller in a
system with an embedded SAS port.
- The mixing of the SSDs and HDDs is as follows:
- SSDs and HDDs cannot be mixed in a logical group when configured
as in mode 1.
- SSDs and HDDs can be mixed when configured as in mode 2: one set
can be SSDs and the other set can be HDDs.
- SSDs and HDDs cannot be mixed when configured as in mode 4 because
the SSDs are not supported by the adapter that is required to configure
the 5887 for
mode 4.
|
| 5888 PCIe storage
enclosure |
PCIe2 (3.1 GB Cache RAID SAS Enclosure 6 Gb
x8) |
- This enclosure is a 1-unit (1U) high I/O drawer that provides
30 hot-swap SSD bays and a pair of integrated SAS controllers. The
SAS controllers provide large write cache and enhanced performance.
- The EXP30 does not support HDDs.
- A maximum of 30 SSDs are supported in this disk drive enclosure.
- The EXP30 can be configured as follows:
- One set of 30 bays and the set is owned by both controllers that
are working together.
- Two logical sets and each of the two controllers owns one of the
logical sets.
- The EXP30 is attached to the system by a PCIe x8 cable that is
installed at the GX ++ slot in the system.
- The system supports connection of the 5887 disk
drive enclosure through the
external SAS ports by using FC 5913, ESA1, or ESA2.
- The system supports only the HDD in the 5887 disk
drive enclosure when this enclosure
is configured as one set of 24 bays (mode 1).
|
| EDR1 PCIe storage enclosure |
PCIe2 (3.1 GB Cache RAID SAS Enclosure 6 Gb
x8) |
- This enclosure is a 1-unit (1U) high I/O drawer that provides
30 hot-swap SSD bays and a pair of integrated SAS controllers. The
SAS controllers provide large write cache and enhanced performance.
- The EXP30 does not support HDDs.
- A maximum of 30 SSDs are supported in this disk drive enclosure.
- The EXP30 can be configured as follows:
- One set of 30 bays and the set is owned by both controllers that
are working together.
- Two logical sets and each of the two controllers owns one of the
logical sets.
- The EXP30 is attached to the system by a PCIe x8 cable that is
installed at the GX ++ slot in the system.
|