The server detected an error in the power system.
Select the system that you are servicing and then perform the indicated PWR1918 procedure.
8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D
8231-E2B, 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
8233-E8B, 8236-E8C
8248-L4T, 8408-E8D, 9109-RMD
8412-EAD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, or 9179-MHD
| Reference code | Action |
|---|---|
| 1xxx 2611 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2622 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2623 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2625 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2626 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2628 | Replace the system backplane (Un-P1). |
| 1xxx 2691 | Perform the following steps:
|
| 1xxx 8450 | At least one VRM is missing from the system unit. Inspect all of the processor cards and memory cards and install the VRMs that are missing. See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 8453 | There is an extra processor regulator in the system. Remove the extra regulator. |
| 1xxx 8454 | A fan at location Un-A3 is installed in a single-socket system. This configuration is not valid. Remove the fan at location Un-A3. |
| 1xxx 8457 and 1xxx 8458 | Low power processor VRMs were installed on the system. The system requires high power processor VRMs. Replace the processor VRMs with the correct part number. |
| Reference code | Action |
|---|---|
| 1xxx 2611 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2622 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2623 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2625 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2626 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2691 | Perform the following steps:
|
| 1xxx 8450 | At least one processor VRM is missing. Inspect all of the processor cards and install the VRMs that are missing. See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 8453 | There is an extra processor regulator in the system. Remove the extra regulator. |
| 1xxx 8458 | Low-power processor VRMs were installed on the system. The system requires high power processor VRMs. Replace the processor VRMs with the correct part number. |
| Reference code | Action |
|---|---|
| 1xxx 2622 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2623 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2624 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2625 | Replace the following, if present, one at
a time, and in the order listed:
|
| 1xxx 2626 | Replace the Ethernet card (Un-P1-C6), if present. |
| 1xxx 2630 | Replace the POWER7® VRM on processor card 1 (Un-P1-C13-C1). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2632 | Replace the memory VRM on processor card 1 (Un-P1-C13-C10). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2634 | Replace processor card 1 (Un-P1-C13). If the problem is not resolved, replace the system backplane (Un-P1). |
| 1xxx 2640 | Replace the POWER7 VRM on processor card 2 (Un-P2-C14-C1). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2642 | Replace the memory VRM on processor card 2 (Un-P1-C14-C10). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2644 | Replace processor card 2 (Un-P1-C14). If the problem is not resolved, replace the system backplane (Un-P1). |
| 1xxx 2650 | Replace the POWER7 VRM on processor card 3 (Un-P2-C15-C1). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2652 | Replace the memory VRM on processor card 3 (Un-P1-C15-C10). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2654 | Replace processor card 3 (Un-P1-C15). If the problem is not resolved, replace the system backplane (Un-P1). |
| 1xxx 2660 | Replace the POWER7 VRM on processor card 4 (Un-P2-C16-C1). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2662 | Replace the memory VRM on processor card 4 (Un-P1-C16-C10). See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 2664 | Replace processor card 4 (Un-P1-C16). If the problem is not resolved, replace the system backplane (Un-P1). |
| 1xxx 3120 | Replace the following, if present:
|
| 1xxx 8450 | At least one VRM is missing from the processor card. Inspect all of the processor cards and install the VRMs that are missing. See System FRU locations for FRU location information for the system that you are servicing. |
| 1xxx 8453 | There is an extra processor regulator in the system. Remove the extra regulator. |
| Reference code | Action |
|---|---|
| 1xxx 262C | Replace the disk drive backplane at location Un-P2-C9. |
| 1xxx 8450 | There are fewer voltage regulator modules than system processor modules. Add another voltage regulator module in the next empty position. |
| 1xxx 8453 | There is an extra voltage regulator module in the system. Remove the extra voltage regulator module. |
| Reference code | Action |
|---|---|
| 1xxx 2620 | Replace the backplane (Un-P1) |
| 1xxx 262C | Replace the disk drive backplane (Un-P2-C9) |
| 1xxx 2611, 2629, 262B, 262D, 262E, 262F | Replace the following:
|
| 1xxx 2630, 2632, 2635, 2636, 2640, 2642, 2645 | Replace the VRM specified by the location code. |
| 1xxx 2634 | Replace the I/O backplane (Un-P2). |
| 1xxx 2700, 2701 | Replace the VRM specified by the location code. |
| 1xxx 2702, 2703 | Replace the disk drive backplane (Un-P2-C9). |
| 1xxx 2704, 2705 | Replace the I/O backplane (Un-P2). |
| 1xxx 3120 | Replace the following, if present:
|
| 1xxx 8450 | There are fewer voltage regulator cards than processor cards. Add another regulator card in the next empty position. |
| 1xxx 8451 | There are too few voltage regulator cards installed. Add another regulator card in the next empty position. |
| 1xxx 8453 | There is an extra processor regulator in the system. Remove the extra regulator. |