subscribe iconSubscribe to this information

Configuring the 5802 disk-drive subsystem

Learn about configuring the 5802 disk-drive subsystem and how to connect and configure it to meet your requirements.

The 5802 SAS disk-drive enclosure can hold up 18 disk drives. The disks in this enclosure can be organized in several different configurations depending on the operating system used, the type of SAS adapter card, and the position of the hard disk drive partitions switch.
Notes:
  • The hard disk drive partitions switch is located at the rear of the 5802 SAS disk-drive enclosure. See Model 5802 and 5877 connector locations. The hard disk drive partitions switch is located just below the SAS connectors.
  • You must power cycle the 5802 SAS disk-drive enclosure if the hard disk drive partitions switch position is changed, in order for the 5802 to sense the new hard disk drive partitions switch position.

The 5802 SAS disk-drive enclosure supports the following operating systems:

To determine the level of software you need to support the 5802 SAS disk-drive enclosure, see the IBM Prerequisite.

Table 1. Hard disk drive toggle switch positions
Operating system Position 1 Position 2 Position 4
AIX
  • Either a (FC 5901) - PCIe Dual - x4 SAS Adapter or
  • two (FC 5903) - PCIe Dual - x4 3Gb SAS RAID Adapters
  • Either two (FC 5901) - PCIe Dual - x4 SAS Adapters or
  • two (FC 5903) - PCIe Dual - x4 3Gb SAS RAID Adapters
Four (FC 5901) - PCIe Dual - x4 SAS Adapters
IBM i Not supported
  • Either two (FC 5901) - PCIe Dual - x4 SAS Adapters or
  • two (FC 5903) - PCIe Dual - x4 3Gb SAS RAID Adapters
Not supported
Linux
  • Either (FC 5901) - PCIe Dual - x4 SAS Adapters or
  • two (FC 5903) - PCIe Dual - x4 3Gb SAS RAID Adapters
  • Either two (FC 5901) - PCIe Dual - x4 SAS Adapters or
  • two (FC 5903) - PCIe Dual - x4 3Gb SAS RAID Adapters
Four (FC 5901) - PCIe Dual - x4 SAS Adapters
Note: FC means feature code.
Tip: If you are going to configure RAID arrays, ensure that you have the following minimum number of available disks for each RAID level:
RAID 0
1 drive minimum per array
RAID 5
3 drives minimum per array
RAID 6
4 drives minimum per array
RAID 10
2 drives minimum per array

For additional SAS RAID controller information for AIX, see SAS RAID controller for AIX .

For additional SAS RAID controller information for Linux, see SAS RAID controller for Linux .

For information related to device parity protection, see Device parity protection.


Send feedback | Rate this page

Last updated: Mon, April 25, 2011