Server specifications provide detailed information for your server, including dimensions, electrical, power, temperature, environment, and service clearances.
Use the following specifications to plan for your server.
| Measurements | Width | Depth | Height | EIA Units1 | Weight |
|---|---|---|---|---|---|
| Metric | 440 mm | 710 mm | 43 mm | 1 | 17 kg |
| English | 17.3 in. | 28.0 in. | 1.7 in. | 37 lb | |
| 1See 0551, 0553, 7014, and 0555 rack configurations for typical configurations when the 0551, 0553, 7014, and 0555 rack is populated with various server models. | |||||
| Measurements | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 635 mm | 851 mm | 330 mm | 20 kg |
| English | 25.0 in. | 33.5 in. | 13.0 in. | 43 lb |
| Measurements | Width | Depth | Height | Weight |
|---|---|---|---|---|
| Metric | 610 mm | 1016 mm | 445 mm | 27 kg |
| English | 24.0 in. | 40 in. | 17.5 in. | 60 lb |
| Feature code for drawer mounted in rack Power distribution Unit (PDU), 0551, 7014-T00, 7014-T42, 0553, and 0555 racks |
0259 | |||
| Electrical characteristics | Properties |
|---|---|
| kVA (maximum) | 0.526 |
| Rated voltage, rated amps, and frequency4 | 100 - 127 V ac (12 A) to 200 - 240 V ac (10 A) at 50 to 60 plus or minus 0.5 Hz |
| Thermal output (maximum) | 1707 Btu/hr |
| Maximum power consumption | 500 W |
| Power factor | 0.95 |
| Inrush current (maximum) | 75 A |
| Leakage current (maximum) | 1.2 mA |
| Phase | 1 |
| Dual power feature code | 7958 (quantity 2) |
| Branch circuit breaker | 20 A (maximum) |
| Environment | Temperature | |
|---|---|---|
| Recommended operating temperature2 | 5 - 35°C (41 - 95°F) | |
| Nonoperating temperature | 5 - 45°C (41 - 113°F) | |
| Shipping temperature | -40 - 60°C (-40 - 140°F) | |
| Operating | Nonoperating | |
| Maximum dew point | 28°C (82.4°F) | 29°C (84.2°F) |
| Noncondensing humidity | 8 - 80% | 8 - 80% |
| Maximum altitude | 3048 m (10 000 ft) | 3048 m (10 000 ft) |
| Product description | Declared A-weighted sound power level, LWad (B) | Declared A-weighted sound pressure level, LpAm (dB) | ||
|---|---|---|---|---|
| Operating | Idle | Operating | Idle | |
| 9115-505 with two hard drives and two power supplies | 6.8 | 6.8 | 52 | 52 |
| 9115-505 with acoustic door (feature code 6248 or 6249) with two hard drives and two power supplies | 6.2 | 6.2 | 44 | 44 |
| Clearances | Front | Back | Left or right | Top |
|---|---|---|---|---|
| Operating | 762 mm (30 in.) | 762 mm (30 in.) | ||
| Nonoperating | 762 mm (30 in.) | 762 mm (30 in.) | 762 mm (30 in.) | 762 mm (30 in.) |
Electromagnetic compatibility compliance: This server meets the following electromagnetic compatibility specifications: FCC (CFR 47, Part 15); VCCI; CISPR-22; 89/336/EEC; BSMI (A2/NZS 3548:1995); C-Tick; ICES/NMB-003; Korean EMI/EMC (MIC Notice 2000–94, Notice 2000–72); People's Republic of China Commodity Inspection Law
Safety compliance: This server is designed and certified to meet the following safety standards: UL 60950; CAN/CSA C22.2 No. 60950–00; EN 60950; IEC 60950 including all National Differences
Notes:
|