subscribe iconSubscribe to this information

ASHRAE declarations

Use the ASHRAE declarations table and figures to determine the measurement reporting requirements defined in the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Thermal Guidelines for Data Processing Environments.

These guidelines are available at ASHRAE Technical Committee.

Table 1. ASHRAE declarations
  Typical Heat Release Airflow nominal Airflow maximum at 35°C (95°F)
Description watts cfm m3/hr cfm m3/hr
Minimum configuration 300 42 71 83 141
Maximum configuration 450 42 71 83 141
Typical configuration 375 42 71 83 141
See Model 7037-A50 server and 7047-185 workstation specifications for weight and overall system dimension.
ASHRAE Class 3
Minimum configuration 1-core, 2.5 GHz processor, 2 GB memory, three hard disk drives, five PCI cards
Maximum configuration 2-core, 2.5 GHz processor, 8 GB memory, three hard disk drives, six PCI cards
Typical configuration 2-core, 2.5 GHz processor, 4 GB memory, three hard disk drives, four PCI cards
Figure 1. Airflow figure for server mounted in a rack
Airflow figure for server mounted in a rack
Figure 2. Airflow figure for stand-alone server
Airflow figure for standalone server

Send feedback | Rate this page