subscribe iconSubscribe to this information

FI01105

FI01105 indicates that the addressed storage device is the failing item.

Complete the following steps:

  1. Is the device location information available in the service action log?
    • No: Continue with the next step.
    • Yes: Replace the failing item. See the disk unit recovery procedures.
  2. Find the IOP address and the device address. See the System reference code format description.
  3. To determine the location of the I/O processor card, see Part locations and location codes. Then complete the following:
    • Find the IOP card location identified by the direct select address.
    • Find the addressed storage device location identified by the device address.
  4. Replace the failing device. Use the device type to determine the part.

Send feedback | Rate this page

Last updated: Tue, October 16, 2012