This system reference code (SRC) is used for a console that fails during an initial program load (IPL) (Operations Console or D-mode IPL).
The following table contains the word 13 nn values in nnmmxxyy for a local console on a network (LAN).
| If word 13 value (nn) is: | nn means: |
|---|---|
| 0 (Embedded flag is on) | |
| 00 | D-mode with no flags |
| 01 | No LAN flags are on. This is the disable flag. |
| 02 | Embedded is enabled. |
| 04 | External is enabled. |
| 06 | Both internal and external enabled. |
| E (Only the external flag is on) | |
| E0 through E5 | Selected LAN card location. |
The following table defines the word 13 mm values in nnmmxxyy for a local console on a network (LAN).
| If word 13 value (mm) is: | mm mean: |
|---|---|
| FF | Managed by an HMC |
The following table defines the word 13 yy values in 0000nnmmxxyy for a local console on a network (LAN).
| If word 13 value (yy) is: | Failure | Word 14 means: | Word 15 means: |
|---|---|---|---|
| 00 | A console was found. | ||
| 01 | No supported hardware was detected or the hardware detected was not expected. For example, you replaced the LAN IOA, so the serial number is different. | In some cases the serial number of the expected adapter might be displayed. If a serial number is displayed, an adapter was previously configured. If you are installing a new server or partition that relies on BOOTP to complete the configuration, you might have to clear this data. See Using the console service functions (65+21). | |
| 02 | LAN IOA failed to report | ||
| 03 | Hardware error | Common error codes 53001A80, 53002AC0: Network, cable, or the LAN adapter might not be operational. 00000000: This error code indicates that the adapter reported, but is not initialized yet. This is not considered an error at this time. The adapter should be activated shortly. For other error codes, contact your service provider. |
Adapter position or serial number of adapter |
| 04 | BOOTP status: If attempts are zero, then BOOTP is ready when called. If attempts have a value, the PC did not respond. | Attempts | Adapter position or serial number of adapter |
| 05 | The server's LAN connection is active, but the
PC failed to connect. Check the following:
|
IP address | Adapter position or serial number of adapter |
| FF | No console resource or port was found. |
The following table defines the word 16 values. The twinaxial console-related SRC is represented by the first 4 characters. The console type value is represented by the last 2 characters in the form xxxxyyzz.
| Word 16 values for xxxxyyzz: | ||
|---|---|---|
| Where xxxx is: | The twinaxial console-related SRC is represented by the first 4 characters. | |
| Where yy is: | 01 | There is a supported, reporting workstation IOA in the tagged IOA location. |
| 02 | There is a reporting communications IOA in the tagged IOA location with at least one reporting port that supports the asynchronous protocol and the needed physical interface. |
|
| 03 | There is a supported, reporting LAN IOA in the tagged IOA location, or a LAN port with the tagged port dynamic reconfiguration connector (DRC). This is used for the Host Ethernet Adapter (also referred to as Integrated Virtual Ethernet). |
|
| 04 | The HMC has been configured. |
|
| 0A | No console IOA tag, no console IOP tag,
and no console port DRC tag found, and the HMC has not been configured.
Note: This
is normal for stand-alone systems because they do not involve tagging.
|
|
| 0B | A physical slot number cannot be determined from the IOA tag. |
|
| 0C | No reporting IOA in the tagged IOA location. |
|
| 0D | More than one valid reporting console IOA in the tagged IOA location. This is an unexpected error that should be reported to your service provider. |
|
| 0E | A reporting IOA was found at the location specified by the console IOA tag, but it was not a communications IOA and was not valid for any other type of console (for example, twinaxial console). |
|
| 0F | An IOP is tagged for the console (not an IOA or host Ethernet adapter port). |
|
| 10 | Reporting LAN ports were found at the location specified by the console IOA tag, but the specific LAN port type (CCIN) is not supported for LAN console. |
|
| 11 | A reporting communications IOA is in the tagged IOA location, but it has no reporting ports. |
|
| 12 | A reporting communications IOA is in the tagged IOA location, but it has no reporting LAN ports and no reporting ports that support Operations Console (direct). |
|
| 13 | No reporting port resource was found with the DRC tag for the console port resource. |
|
| 14 | A reporting port was found with the DRC tag for the console, but it did not qualify to be used with Operations Console |
|
| Where zz is: | 00 | Not defined by user (old default value) |
| 01 | Twinaxial console |
|
| 02 | Operations Console (direct) |
|
| 03 | Operations Console (LAN ) |
|
| 04 | Hardware Management Console (HMC) |
|
The following table defines the word 17 values for a local console that is directly attached.
| Direct cable | |||
|---|---|---|---|
| If word 17 value is: | Failure | Word 18 means: | Word 19 means: |
| 1 | Asynchronous adapter not detected | ||
| 2 | No cables detected | Adapter position | Adapter type |
| 3 | Wrong cable detected | Adapter position | Cable ID |
| 4 | Port in use | Adapter position | Adapter type |
| FA | Not configured for direct cable | ||