subscribe iconSubscribe to this information

Locations

Learn how to locate field replaceable units (FRUs) by using logical and physical location codes.

Note: The known logical location codes for this unit are listed next to the corresponding physical location in the following information. If you are working with a logical location code for this unit and it is not listed in the following information, contact your next level of support.

The following diagrams show field replaceable unit (FRU) layout in the expansion unit. Use these diagrams with the following tables.

Note: Some units may have labels that designate location codes other than those shown in the following illustrations and tables. If that is the case, use the location codes shown in the following illustrations and tables.
Figure 1. Front view of the expansion unit
Front view of the expansion unit
Figure 2. Back view of the expansion unit
Back view of the expansion unit
Figure 3. Top view of the expansion unit
Top view of the expansion unit

The following table gives the components available for callout on the expansion units, and matches those components with the FRU containing the component. For part numbers associated with failing components, see 0595, 5095, and 7311-D20 system parts.

Table 1. FRU locations and failing components for the expansion unit
Failing item name Physical location code Identify LED
Backplane
  • SPCN
  • Card enclosure or backplane
  • Multi-adapter bridge (all)
Un-P1 Yes
PCI adapter in slot 1 Un-P1-C01 Yes
PCI adapter in slot 2 Un-P1-C02 Yes
PCI adapter in slot 3 Un-P1-C03 Yes
PCI adapter in slot 4 Un-P1-C04 Yes
RIO/HSL adapter Un-P1-C05 Yes
RIO/HSL adapter connector (bottom connector Un-P1-C05-00 Yes
RIO/HSL adapter connector (top connector) Un-P1-C05-01 Yes
PCI adapter in slot 6 Un-P1-C06 Yes
PCI adapter in slot 7 Un-P1-C07 Yes
PCI adapter in slot 8 Un-P1-C08 Yes
PCI bridge set 1

Un-P1
Un-P1-C01
Un-P1-C02
Un-P1-C03
Un-P1-C04

 
PCI bridge set 2

Un-P1
Un-P1-C06
Un-P1-C07
Un-P1-C08

 
EPO connector (J11) Un-P1-T1  
UPS connector (J14) Un-P1-T2  
SPCN connector (J15) Un-P1-T3  
SPCN connector (J16) Un-P1-T4  
Rack beacon connector Un-P1-T5  
Fan 1 Un-A1 Yes
Fan 2 Un-A2 Yes
Fan 3 Un-A3 Yes
Fan 4 Un-A4 Yes
Device physical locations
Disk drive 1 Un-DB1-D01  
Disk drive 2 Un-DB1-D02  
Disk drive 3 Un-DB1-D03  
Disk drive 4 Un-DB1-D04  
Disk drive 5 Un-DB1-D05  
Disk drive 6 Un-DB1-D06  
Disk drive 7 Un-DB2-D07  
Disk drive 8 Un-DB2-D08  
Disk drive 9 Un-DB2-D09  
Disk drive 10 Un-DB2-D10  
Disk drive 11 Un-DB2-D11  
Disk drive 12 Un-DB2-D12  
Power supply 1 Un-E1  
Power supply 2 Un-E2  
Disk drive backplane Un-DB1  
Disk drive backplane Un-DB2  
Notes:
  1. J11 is an RPO connection, J14 is an uninterruptible power supply connector, J15 is an SPCN 1 connector, and J16 is an SPCN 2 connector.
  2. Multi-adapter bridge domains are labeled PCI Bridge Set inside the expansion unit.
  3. The following table provides information necessary to identify the IOP to which an IOA is assigned.
    • The left column indicates the domain in which IOA assignment is allowed.
    • The right column is used to determine the IOP to which an IOA is assigned.
    • The first position in the list must be an IOP. The remaining positions may be IOPs or IOAs. IOAs are assigned to the first IOP located to their left in the list. Although IOAs can be manually reassigned using SST/DST, the IOA assignments return to the default order after each IPL.
      Table 2. IOA domains and assignments
      Multi-adapter bridge domain / PCI bridge set IOA assignments rules
      C01 - C04 C01, C02, C03, C04
      C06 - C08 C06, C07, C08

Send feedback | Rate this page