Learn how to locate field replaceable units (FRUs) by using logical and physical location codes.
The following diagrams show field replaceable unit (FRU) layout in the expansion unit. Use these diagrams with the following tables.


The following table gives the components available for callout on the expansion units. It matches those components with the FRU containing the component. The other columns give location information, a link to a removal and replacement procedure, and additional information.
| Failing item name | Physical location code | Identify LED |
|---|---|---|
| Expansion unit | Un | |
| Fan | ||
| Fan | Un-A1 | Yes |
| Power supplies | ||
| Power supply 1 | Un-E1 | Yes |
| Power supply 2 | Un-E2 | Yes |
| Backplane | ||
| I/O backplane | Un-P1 | Yes |
| I/O backplane ports | ||
| Rack beacon connector | Un-P1-T1 | |
| Adapters | ||
| PCI adapter in slot 1 | Un-P1-C1 | Yes |
| PCI adapter in slot 2 | Un-P1-C2 | Yes |
| PCI adapter in slot 3 | Un-P1-C3 | Yes |
| PCI adapter in slot 4 | Un-P1-C4 | Yes |
| PCI adapter in slot 5 | Un-P1-C5 | Yes |
| PCI adapter in slot 6 | Un-P1-C6 | Yes |
| PCI bridge set 1 | Un-P1 |
|
| PCI bridge set 2 | Un-P1 |
|
| RIO/HSL adapter | Un-P1-C7 | Yes |
| RIO/HSL adapter connector (top connector), port 0 | Un-P1-C7-00 |
Yes |
| RIO/HSL adapter connector (bottom connector), port 1 | Un-P1-C7-01 |
Yes |