- The asterisk (*) is an accepted wildcard.
- SRCs are strings of either 6 or 8 alphanumeric characters in the formats ΧΧΧΧΧΧ or ΧΧΧΧΧΧΧΧ . Examples: 110000AD, C6003900, B7*988>
- Progress codes are strings of 8 characters that begin with a C (except CB) or D (except DA). Examples: C1001F0D, D101C00F, D11A1xxx, D11A1*, D1*B0FF
- HMC error codes and messages are strings of 8 characters that begin with an H or strings of 6 characters that begin with a zero (0), and they do not include a hyphen. Examples: HSCL0003, HSCP0021, HSCI0104, 0x0007, 0*0104
- AIX diagnostic messages are strings of 3 or 4 characters. Examples: 887, 2621, c33, c54, 0c0, 700, 558
- SRNs are either strings of 5 hexadecimal numbers or numeric strings in the following formats xxxxx, xxx-xxx, xxx-xxxx, xxxx-xxx, xxxx-xxxx. Examples: 301C0, 733-120, 2502-3010
- Symbolic FRUs are procedures used to diagnose problems with features and parts. Examples: ACMODUL, AIRMOVR, CAPACTY, LPARCFG, FWNIM, PWRSPLY, UC235
- Failing function codes represent functions within the system unit. Examples: 11A, 201, 2E01, E30, B71
- Failing item codes indicate which is the failing item. Examples: FI00021, FI00090, FI00718, FI01140
- Isolation procedures are are used together with diagnostic programs to isolate problem. Examples: RIOIP11, MABIP51, COMPIP1, PWR1905, FSPSP23, FSPSP33
|
|