POWER6 information
Hardware SRC formats
SRC format examples.
Notes:
- Other formats exist; if necessary contact your next level of support.
- For more information on formats 60–63, see Licensed Internal Code detected problem reference code formats.
| SRC Word Number | Panel function, digits x to y (from left to right) | IOP SRC format 13 | IOP SRC format 17 | Device SRC format 27 | IOP detected a failure format 29 | Licensed Internal Code SRC Format 60 | Licensed Internal Code SRC format 61 | Licensed Internal Code SRC format 62 | Licensed Internal Code SRC format 63 |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 11, 1-8 | TTTT RRRR | TTTT RRRR | tttt rrrr | B0XX RRRR | A6xx RRRR | B6xx RRRR | B6xx RRrr or B7xx Rrrr | A600 RRRR |
| 2 | 12, 1-8 | MIGV EP13 | MIGV EP17 | MIGV EP27 | MIGV EP29 | MIGV EP60 | MIGV EP61 | MIGV EP62 | MIGV EP63 |
| 3 | 12, 9-16 | BBBB Ccbb | BBBB Ccbb | BBBB Ccbb | BBBB Ccbb | PPPP 0000 | cccc cccc | cccc cccc | AAAA BBBB |
| 4 | 12, 17-24 | aaaa aaaa | aaaa aaaa | aaaa aaaa | SAPP UUFF | BBBB Ccbb | pppp pppp | pppp pppp | CCCC DDDD |
| 5 | 12, 25-32 | TTTT LMMM | TTTT LMMM | tttt lmmm | TTTT FMMV | aaaa aaaa | qqqq qqqq | qqqq qqqq | EEEE FFFF |
| 6 | 13, 1-8 | uuuu uuuu | tttt lmmm | TTTT LMMM | tttt lmmm | tttt mmmm | qqqq qqqq | qqqq qqqq | GGGG HHHH |
| 7 | 13, 9-16 | uuuu uuuu | ZZZZ rrrr | ZZZZ RRRR | zzzz rrrr | ssss ssss | 0000 0000 | BBBB Ccbb | JJJJ KKKK |
| 8 | 13, 17-24 | uuuu uuuu | ssss ssss | ssss ssss | 0sss ssss | NNNN 0000 | 0000 0000 | TTTT MMMM | TTTT 0MMM |
| 9 | 13, 25-32 | uuuu uuuu | uuuu uuuu | uuuu uuuu | uuuu uuuu | 0000 0000 | 0000 0000 | 0000 0000 | SSSS SSSS |
| SRC format | Description |
|---|---|
| AAAA | Type of I/O Bus (see Logical address format — field 'A'). |
| aaaa | Unit address. |
| BBBB | System Bus Number (see Logical address format — field 'B'). |
| BBBBCcbb | Bus, bus, bus, bus, card, card, and
board, board address (Direct Select Address or DSA).
|
| CCCC | System Board Number (see Logical address format — field 'C'). |
| cccc cccc | Component reference code. Format 62 varies by component. |
| DDDD | System Card Number (see Logical address format — field 'D'). |
| EEEE | (see Logical address format — Unit Address type — field 'E'). |
| FFFF | (see Logical address format — Unit Address type — field 'F'). |
| GGGG | (see Logical address format — Unit Address type — field 'G'). |
| HHHH | (see Logical address format — Unit Address type — field 'H'). |
| JJJJ | (see Logical address format — Unit Address type — field 'J'). |
| KKKK | (see Logical address format — Unit Address type — field 'K'). |
| LMMM | Level indicator plus 3" digit model number (for example, 0001). |
| lmmm | Level indicator plus 3" digit model number of failing device. |
| 0MMM | Model number of failing device (i.e. MMM='001'). |
| MIGV EP | General system status. |
| NNNN | Number of disk device facilities that are missing. |
| PPPP | Cause code. |
| pppp pppp | Programming reference code. |
| qqqq qqqq | Programming reference code qualifier. |
| RRRR | Unit reference code (URC). |
| rrrr | Outboard failing unit reference code (URC). |
| SAPP UUFF | Unit address. |
| SSSSSSSS | System Reference Code — this SRC is used to determine why the primary console failed to respond. |
| ssss | Serial number of failing unit. |
| TTTT | Type number or card identification number (hex). |
| tttt | Outboard failing unit type number (i.e. 6607). |
| uuuu | Unit-specific data. |
| ww | SRC type. |
| ZZZZ | Reserved. |