The Failed Authentication state can occur when the HMC access password for the managed
system is not valid.
- Do you have an HMC password?
- Yes: Enter the HMC password and choose from the following options:
- If the managed system goes to Operating, Power Off, or Standby,
the authentication was successful. This ends the procedure.
- If the managed system goes to No connection, Incomplete, Recovery,
or Error state, refer to Correcting the managed system operating state.
- No: Do you have an ASMI admin password?
- Yes: Continue with step 2.
- No: Contact your next level of support to request CE login. Then
continue with step 2,
using CE login instead of admin password for step 2.a.
- Perform the following steps:
- Login to the ASMI with admin authority.
- Select Login Profile.
- Select Change Password.
- In the User ID to change field, select HMC.
- Enter the ASMI's admin password in the Current password
for user ID admin field.
Note: Do not enter the HMC user password. Enter the
ASMI's admin password.
- Enter a new HMC access password twice and click Continue.
- From the HMC's Server Management window,
select Update the managed system password.
- Input the new password that was set in step 2.f. This
ends the procedure.
- If the problem is not resolved by any of the above steps, contact
your next level of support or your hardware service provider.