To complete this procedure, you might need the latest set of Save
System (SAVSYS) or SAVSTG tapes that were made before the problem occurred,
and three blank tapes.
To complete this
procedure, you might need the latest set of Save System (SAVSYS) or SAVSTG
tapes that were made before the problem occurred. You will also need three
blank tapes.
- Are you exchanging a disk unit because a disk unit failure caused
system operations to stop completely?
- Yes: Continue with the next step.
- No: You may be able to use the Remove Units from
Configuration function of DST. This function allows you to move all data from
the disk unit you want to exchange to the other disk units in the same auxiliary
storage pool (ASP). Go to step 20.
- Perform an IPL to Dedicated Service Tools (DST)
(see Performing an IPL
to DST). Does the Use Dedicated Service Tools (DST) display
appear?
- Yes: Go to step 5.
- No: Continue with the next step.
- Did any messages regarding missing disk units appear?
- Yes: Ignore the messages and go to step 5.
- No: Continue with the next step.
- Repeat step 2. Does the same SRC occur again?
- Yes: The customer data is not recoverable. Go
to step 7.
- No: Use the new SRC to correct the problem. Go
to Start of call procedure. This
ends the procedure.
- From the Use Dedicated Service Tools (DST) display,
perform the following to save the customer data from the failing disk unit:
- Select .
- On the Select Disk Unit Data to Save display, select the disk
unit from which you want to save the data. Record the ASP of the disk unit
that you are saving.
Note: If the disk unit is missing, you cannot
save the customer data to tape at this time. Go to step
7.
- Install a tape in the tape unit. The Specify Volume
Identifier prompt appears.
- Enter the volume identifier for the tape. Write down
the tape volume identifier. You will use the tape volume identifier later
in this procedure. The Select Tape Unit prompt appears.
- Select the tape unit that you loaded with a tape. The
Function Status display shows the percent of disk data saved.
Note: If the
tape volume identifier that you entered does not match the tape volume identifier
on the tape you loaded, the Device Intervention Required prompt appears. The
message "Wrong volume loaded" appears at the bottom of the display. Select
the Format option and press Enter to continue the save
operation.
- If the tape is full, the Device Intervention display appears. The message "Load next volume" appears at the bottom of the display.
Insert the next tape into the tape unit and select the option to retry, and
then press Enter to continue the save operation.
- Continue saving the disk unit data until the status of the save
is complete.
Note: Customer data is not recoverable if one of the
following occurs:
- The copy operation does not complete.
- A large number of unreadable pages must be copied from the disk unit.
- Does the display show that the status of the save is complete?
- No: Continue with the next step.
- Yes: Go to step 8.
- Have you already exchanged the storage IOA?
- Yes: Continue with the next step.
- No: Perform the following:
- Power off the system.
- Exchange the storage IOA (see Removing and replacing parts). If you do not know the
part number, see Finding
part locations.
- Perform an IPL to Dedicated Service Tools (DST) (see Performing an IPL to DST).
- Choose from the following:
- If the same SRC occurs, go to step 8.
- If a different SRC occurs, use it to correct the problem. Go to Start of call procedure.
- If no SRC occurs, then the problem has been resolved. This
ends the procedure.
- Power off the system and exchange the failing
disk unit (see Disk drive).
- Did you just exchange disk unit 1 in the system unit?
- Yes: Go to step 11.
- No: Format and initialize the new disk unit by
performing the following:
- Perform an IPL to DST (see Performing
an IPL to DST). You may ignore any messages regarding missing disk
units.
- From the Use Dedicated Service Tools (DST) display, select .
- Select the disk unit you wish to initialize and format.
- Press F10 on the confirmation display. The system
formats and initializes the new disk unit. The display shows when the status
is complete (this may take 30 minutes or longer). Continue with the next step.
- Is most of the customer data recoverable (see step 5)?
- No: Go to step 18.
- Yes: Restore the customer data from the tape to
the new disk unit by performing the following:
- Return to the Work With Disk Unit Recovery display and select Restore
disk unit data.
- Enter the tape volume identifier. This is the volume identifier that you
entered during the save procedure.
- Install into the tape unit the first tape that the data was saved to.
- On the Select Tape Unit display, select the tape unit that you want the
data restored from.
- On the Restore Disk Unit Data display, select the disk unit on which you
want to restore the data.
- Press F10 to confirm the restore. The Function
Status display shows the percentage of customer data restored. The system
will IPL to the Use Dedicated Service Tools (DST) display when the restore
has completed.
Note: Any damaged objects that were restored must be loaded
again by the customer. Refer the customer to the
Backup and Recovery 
book.
- The system is ready for the next IPL. This ends the procedure.
- Is the customer data recoverable (see step 5)?
- Did you get a Disk Configuration Error Report with a Unit has
incorrect logical partition configuration warning?
- No: Continue with the next step.
- Yes: You have logical partitions that need to be
recovered before you can continue with this disk unit recovery procedure.
Perform the following:
- Select the Use Dedicated Service Tools (DST) option
from the IPL or Install the System display.
- Enter the password 22222222. If this password is not valid, ask
the customer for the correct password.
- From the Use Dedicated Service Tools (DST) display, select .
- Review the information on the Select Disk Unit for Configuration Data
Recovery display. Select the disk unit with the most recent date and the correct
system serial number, and then press Enter. The system
automatically copies the configuration data to the primary partition's load
source, and performs an IPL. Continue with the next step.
- Restore the customer data from the tape to the new disk unit by
performing the following:
- Select Use Dedicated Service Tools (DST) from
the IPL or Install the System display.
- Enter the password 22222222. If this password
is not valid, ask the customer for the correct password.
- From the Use Dedicated Service Tools (DST) display, select .
- Enter the tape volume identifier. This is the volume
identifier that you entered during the save procedure.
- Install the first tape to which the data was saved in the tape
unit.
- On the Select Tape Unit display, select the tape unit that you
want the data restored from.
- On the Restore Disk Unit Data display, select the disk unit
on which you want to restore the data.
- Press F10 to confirm the restore. The Function Status display shows the percentage of customer data restored.
Note: When
the load-source disk is restored, the system automatically performs an IPL
to the Use Dedicated Service Tools (DST) display. This occurs after the restore
operation completes.
- When all customer data from the tape to the disk restores successfully,
the display shows that the status of the restore operation as complete. Press Enter to complete the restore operation.
- Power off the system.
Note: Any damaged objects that
were restored must be loaded again by the customer. Refer the customer to
the
Backup
and Recovery 
book.
- The system is ready for the next IPL. This
ends the procedure.
- Perform an IPL from removable media and select
the option to install Licensed Internal Code and recover configuration. See Utilities to Install
and Restore Licensed Internal Code. Then continue with the next step.
- Did you get a Disk Configuration Error Report with a Unit has
incorrect logical partition configuration warning?
- No: Continue with the next step.
- Yes: You have logical partitions that need to be
recovered before you can continue with this disk unit recovery procedure.
Perform the following:
- Enter Use Dedicated Service Tools (DST) from the
IPL or Install the System display.
- Enter the password 22222222. If this password is not valid, ask
the customer for the correct password.
- From the Use Dedicated Service Tools (DST) display, select .
- Review the information on the Select Disk Unit for Configuration Data
Recovery display. Select the disk unit with the most recent date and the correct
system serial number, and then press Enter. The system
will automatically copy the configuration data to the primary partition's
load source, and then perform an IPL. Continue with the next step.
- The system ASP will be cleared because customer data was not recoverable. Recover the configuration to disk unit 1 in the system unit by performing
the following:
- Enter Use Dedicated Service Tools (DST) from
the IPL or Install the System display.
- Enter the password 22222222. If this password
is not valid, ask the customer for the correct password.
- From the Use Dedicated Service Tools (DST) display, select .
- Select Recover configuration on the Work
with Disk Unit Recovery display. This option assembles the system
configuration information on disk unit 1 in the system unit. Continue with
the next step.
Note: A warning message will appear stating that recovering
the configuration destroys all system data.
- Did a message appear stating that your request to recover the configuration
was not successful?
- Yes: You are working on a system with only one
disk unit, and the recover configuration function cannot be performed with
only one disk unit. Go to step 18.
- No: Go to step 19.
- Because the disk data was not recoverable, clear
the auxiliary storage pool (ASP) to which the disk unit is assigned by performing
the following:
- Return to the Work with Disk Units display. Select .
- Enter the Delete option for the ASP that
you recorded in step 5, and
confirm the deletion.
- Return to the Work with Disk Units display, and select .
- On the Select Configured Unit to Replace display, select the
configured disk unit to exchange.
- On the Select Replacement Unit display, select the new disk
unit.
- Press Enter to confirm the replace operation
(this operation takes 10 to 15 minutes to complete). This
ends the procedure. The auxiliary storage pool to which the disk
unit is assigned was erased. The customer must restore the data to the auxiliary
storage pool. Refer the customer to the Backup and Recovery
book.
- The ASP to which the failing disk unit was assigned
was erased. The customer should perform one of the following:
- If the disk unit you exchanged is in ASP 1, refer the customer to the Backup and
Recovery
book to restore the operating system and all customer data. This
ends the procedure.
- If the disk unit is in a user ASP (ASP 2 through ASP 16), data in the
ASP is lost. See the Backup and Recovery
book. This ends the procedure.
- The remaining steps of this procedure require
a dedicated system. Have the customer do a normal power-off procedure
of the system. Then continue with the next step.
- Perform an IPL to DST (see Performing an IPL to DST). Is the IPL or
Install the System display shown, or is DST available?
- No: Go to step 2.
- Yes: Select Use dedicated service tools
(DST) on the display or use a function key. Have the customer
enter their password to get to the Use Dedicated Service Tools (DST) display.
Continue with the next step.
- Perform the following:
- From the Use Dedicated Service Tools (DST) display, select .
- Record the ASP, unit, serial number, type, and resource name
of the disk unit.
- On the Display Disk Configuration Status display, ensure the
following:
- The disk unit is not the load-source disk unit (disk unit 1).
- No disk units are missing from the configuration (indicated by an asterisk
(*) next to the unit number).
- The status field of the disk unit to be removed shows Configured.
Are all of the above conditions true?
- Yes: Continue with the next step.
- No: You cannot use the Remove Units from Configuration
function. Go to step 2.
- Return to the Display Disk Configuration display and select Display
disk configuration capacity. Does the % Used field
for the disk unit to be removed show an asterisk (*)?
- No: Continue with the next step.
- Yes: You cannot use the Remove Units from Configuration
function. Go to step 2.
- Return to the Work with Disk Units display and perform the following:
- Select .
- Select the disk unit to analyze.
- Press F10 to analyze the disk unit surface.
- Wait until the Analyze function is complete. This will take
several minutes.
Are there any pages with errors?
- No: Continue with the next step.
- Yes: You cannot use the Remove Units from Configuration
function. Go to step 2.
- Return to the Work with Disk Units display and perform the following:
- Select .
- Select the disk unit to be removed. If the disk unit does not
display, go to step 2.
- If the Confirm Continuation display appears, press Enter to
continue. Wait for the next display.
- If there is enough storage in the ASP, the Confirm Remove Disk
Units display appears. If there is not enough storage, an error
message display appears. Does any error message display appear?
- No: Continue with the next step.
- Yes: Go to step 2.
- Press Enter to verify the Remove Disk Units
function. The Remove Disk Units function takes several minutes.
When it is complete, a message will appear stating whether it was successful.
Was the Remove Disk Units function successful?
- Yes: Continue with the next step.
- No: Go to step 2.
- On the Work with ASP Configuration display, select Display
disk configuration capacity. Press F11 twice
to display non-configured units. Is the unit you removed shown as a non-configured
unit?
- Yes: Continue with the next step.
- No: Go to step 2.
- You can exchange the disk unit at a later time because the disk
unit is removed from the configuration Do you want to exchange
the disk unit now?
- Yes: Continue with the next step.
- No: This ends the procedure.
- Power off the system and exchange the failing
disk unit (see Disk drive).
- Format and initialize the new disk unit by doing the following:
- Perform an IPL to DST (see Performing an IPL to DST).
- From the Use Dedicated Service Tools (DST) display, select .
- Select the disk unit you wish to initialize and format.
- Press F10 on the confirmation display.
- The system initializes and formats the new disk unit. The display shows when the status is complete (this may take 30 minutes
or longer). Continue with the next step.
- In this step, you use the ASP, unit, serial number, type, and resource
name information that you recorded in step 22. Perform the following:
- Return to the Work with Disk Units display and select .
- Specify the ASP from which the disk units were removed.
- Select the unit to add to the ASP.
- When the Confirm Add Units display appears, press Enter to
continue. Wait for the next display.
- The Add Disk Units function takes several minutes. When
it is complete, a message appears stating whether it was successful. Was the
Add Disk Units function successful?
- No: Continue with the next step.
- Yes: On the Work with ASP Configuration display,
select Display disk configuration capacity. The unit
you that added should be shown in the correct ASP. This ends the
procedure.
- Do you have more field replaceable units (FRUs) to exchange?
- Yes: Go to step 29.
- No: Ask your next level of support for assistance. This
ends the procedure.