You might want to clear any cached information from other iSCSI
HBAs your adapter communicated with in the past. Use the procedure in this
section to accomplish this task.
Important: performing this procedure will likely erase
iSCSI boot information, making it necessary to reconfigure the boot iSCSI
HBA settings.
- Start the configuration utility if it is not already running. For
instructions see, Start the iSCSI HBA configuration utility.
Note: The procedure below starts at the Fast!UTIL Options menu.
- Highlight Configuration Settings using the
up or down arrow keys and press Enter.
- Highlight Clear persistent targets using
the up or down arrow keys and press Enter.
- On the next screen, highlight Clear persistent targets using
the up or down arrow keys and press Enter. The text in the Clear Persistent
Targets pane will change to Clearing Persistent Targets while the clear is
in progress. It might take several minutes to complete.
- Once the clear is complete, the text in the Clear Persistent Targets
pane will change to Persistent Targets Cleared; hit any key to return to the Configuration
Settings menu.
- Press Esc to return to the Fast!UTIL Options menu.