subscribe iconSubscribe to this information

Failed and non-reporting resources

View location information and display a list of the packaging hardware resources that either failed or did not report at the last IPL.

The Failed and non-reporting hardware resources option appears on the Hardware Service Manager display when the system is in the full or limited paging environment. It allows you to display a list of the logical hardware resources that either failed or did not report to the system at the last IPL.

Note: To view location information and display a list of the packaging hardware resources that either failed or did not report at the last IPL, select the Associated packaging resource(s) option on the Failed and Non-Reporting Logical Hardware Resources display.

A failed resource that reports to the system at the time of the IPL might have a problem with its operation. On the Failed and Non-Reporting Logical Hardware Resources display, Failed appears in the Status column to indicate a failed resource. The failed resources appear at the top of the list.

A non-reporting resource does not report to the system at the time of the IPL. On the Failed and Non-Reporting Logical Hardware Resources display, a question mark symbol (?) appears next to the resource description field to indicate a non-reporting resource. The status of a non-reporting resource is Unknown.
Note: For more information on symbols, see Symbols on the Hardware Service Manager displays.

A failed or non-reporting resource indicates that one of the following has occurred:

Selecting the Failed and non-reporting hardware resources option is a quick way to display failed and non-reporting resources on the system. For information on other ways to display failed and non-reporting resources, see Display failed resources or Display non-reporting resources.

Figure 1. Example Failed and Non-Reporting Logical Hardware Resources display
            Failed and Non-Reporting Logical Hardware Resources
 
Type options, press Enter.
  2=Change detail    4=Remove    5=Display detail    6=I/O Debug
  7=Verify           8=Associated packaging resource(s)
 
                                                               Resource
Opt  Description                    Type-Model  Status         Name
 _   Communications IOP             2626-001    Failed         CC04
 _   Communications IOA             2626-001    Failed         LIN04
 _   Communications Port            2626-001    Failed         CMN05
 _   Communications IOP       ?     2626-001    Unknown        CC01
 _   Communications IOP       ?     2623-001    Unknown        CC03
 _   Communications IOP       ?     2619-001    Unknown        CC05
 _   Communications IOA       ?     2626-001    Unknown        LIN01
 _   Communications IOA       ?     2619-001    Unknown        LIN05
 _   Communications IOA       ?     2609-001    Unknown        LIN02
 _   Communications Port      ?     2619-001    Unknown        CMN08
 _   Communications Port      ?     2626-001    Unknown        CMN02
 _   Communications Port      ?     2609-001    Unknown        CMN03
 _   Communications Port      ?     2609-001    Unknown        CMN04
 _   Workstation IOP          ?     916A-001    Unknown        WS01
 _   Workstation IOA          ?     916A-001    Unknown        CTL01
 _   Display Station          ?     3196-0A1    Unknown        DSP001
                                                                        More...
F3=Exit      F5=Refresh      F6=Print      F12=Cancel
 
If no failed resources or non-reporting resources exist, the following informational message appears:
No failed or non-reporting logical hardware resources were found.
If the system finds only non-reporting resources and no failed resources, the Failed and Non-Reporting Logical Hardware Resources display appears with the list of non-reporting resources and the following message:
No failed logical hardware resources
were found.
If the system finds only failed resources and no non-reporting resources, the Failed and Non-Reporting Logical Hardware Resources display appears with the list of failed resources and the following message:
No non-reporting logical hardware resources
were found.
The options on the failed or non-reporting displays are the same options that are available for logical resources:
  • Change detail
  • Remove
  • Display detail
  • I/O debug
  • Verify
  • Associated packaging resource

For more information on these options, see Collecting information and performing functions from the Hardware Service Manager displays.


Send feedback | Rate this page