Learn about the configuration rules for RIO/HSL.
When you set up the expansion unit, observe the configuration rules as shown in the following table.
| Feature | Maximum number of ports | Maximum number of loops | Maximum number of expansion units per loop | Maximum number of supported expansion units |
|---|---|---|---|---|
| 9111-520 or 9111-285 | 2 | 1 | 4 | 4 |
| 9405-520 or 9406-520 | 2 | 1 | 6 | 6 |
| 9113-550 | 4 | 2 | 4 | 8 |
| p5 550Q, or 720 | 4 | 2 | 6 | 12 |
| 9406-550 | 4 | 2 | 6 | 12 |
| 9117-570 | 16 | 8 | 4 (7 with a 9411-100 attachment1) |
14 (20 with a 9411-100 attachment) |
| 9406-570 | 16 | 8 | 6 | 48 |
| 9118-575 | 2 per node | 1 per node | 1 | 1 |
| 9119-590 | 24 | 12 | 1 (7 with a 9411-100 attachment2) |
8 (14 with a 9411-100 attachment) |
| 9119-595 | 48 | 24 | 1 (7 with a 9411-100 attachment2) |
12 (18 with a 9411-100 attachment) |
| 9406-595 | 62 | 31 | 6 | 96 |
Notes:
|
||||