HSCL01xx managed system error codes

These error codes can be displayed in a window that is displayed on the HMC screen during system configuration and operations.
Back to HSCL error codes page
HSCL01xx error codes Message Recovery action
HSCL01F7 Unable to get the current time from the managed system.
  1. Rebuild the managed system. For details, see Updating managed system or frame information.
  2. Try the task again.
  3. If the problem persists, contact your next level of support or your service provider.
HSCL01F8 This property cannot be altered.  
HSCL01F9 Could not create managed system instance in object manager.
  1. Try the task again.
  2. Shut down and restart the HMC. For details, see Shutting down, rebooting, and logging of the HMC.
  3. Try the task again.
HSCL01FA The managed system is already powered off. The managed system was already powered off before your attempt to power it off. No action is required.
HSCL01FB The number of parameters is incorrect. Specify a different value.  
HSCL01FC The parameter specified is not valid. Specify a different value.  
HSCL01FD Power on failed. Try again.
  1. Retry starting the managed system.
  2. If the problem persists, contact your next level of support or your service provider.
HSCL01FE The managed system is already powered on.  
HSCL01FF Could not rebuild. Shut down and restart the Hardware Management Console.
  1. Retry the task.
  2. If it fails again, shut down and restart the HMC. For details, see Shutting down, rebooting, and logging of the HMC.
  3. Check the state of the managed system. Refer to Correcting the managed system operating state and perform the appropriate procedure to put the managed system in the correct state.
  4. Try the task again.
  5. If the problem persists, contact your next level of support or your service provider.