| HSCFxxxx error codes | Message | Recovery action |
|---|---|---|
| HSCF0001 | Select at least one Licensed Internal Code type to be updated. | |
| HSCF0002 | Flash side selected for next activation: t-side | No recovery action is needed. |
| HSCF0003 | Flash side selected for next activation: p-side Attention: Selecting p-side for next activation will disable concurrent LIC update. The selection is for the next activation. To make it the currently active side, the target must be activated. |
To switch to the temporary side, refer to Working with the temporary and permanent side of the service processor. |
| HSCF0004 | An error occurred trying to survey the target {0}. The task will be terminated. | |
| HSCF0005 | Managed System and Power LIC is selected for updating, but no target is currently selected. Ensure that the Managed System and Power LIC checkbox is not checked, or click Advanced Options to select a target. | |
| HSCF0006 | I/O LIC is selected for updating, but no device is currently selected. Ensure that the I/O LIC checkbox is not checked, or click Advanced Options to select a device. | |
| HSCF0007 | An error was encountered while reconfiguring the target {0} for updating through the Hardware Management Console. The selected action can not be performed at this time. | |
| HSCF0008 | The selected installation type indicates to install
and activate concurrently, but one or more selected targets have a disruptive
concurrency status. Either select a different installation type, or ensure there are no targets selected with a concurrency status of "All must be disruptively activated." |
|
| HSCF0009 | Failure importing the following I/O microcode {0} | |
| HSCF0010 | I/O level details are not available. | |
| HSCF0011 | Select a row in the table, and try the operation again. | |
| HSCF0012 | Permanent flash side is active. | To switch to the temporary side, refer to Working with the temporary and permanent side of the service processor. |
| HSCF0013 | There are no applicable levels for displaying cover letter information. | |
| HSCF0014 | At least one target has its flash p-side active. Contact a user with service mode authority to use the Flash Side Selection task to make the flash t-side active, and then start this task again. The affected target(s): {0}. | To switch to the temporary side, refer to Working with the temporary and permanent side of the service processor. |
| HSCF0015 | An internal code error occurred on the target {0}. The task will be terminated | |
| HSCF0016 | The operation failed because the drive is in use or can not be accessed for some other reason. | |
| HSCF0017 | The DVD does not contain any applicable upgrade updates. Insert another DVD, and click {0}. | |
| HSCF0018 | At least one target does not have an applicable upgrade update. Start the task again without selecting the following target(s): {0}. | |
| HSCF0019 | Retrieving updates. | |
| HSCF0020 | Installing updates. | |
| HSCF0021 | Activating updates - Power Off. | |
| HSCF0022 | Activating updates - Restarting FSP. | |
| HSCF0023 | Activating updates - Power On. | |
| HSCF0024 | Activating updates - FSP. | |
| HSCF0025 | Activating updates - PHYP. | |
| HSCF0026 | Activating updates - PFW. | |
| HSCF0027 | Update complete. | |
| HSCF0028 | Removing updates. | |
| HSCF0029 | Saving accepted level. | |
| HSCF0030 | Saving accepted level. | |
| HSCF0031 | Unable to contact the IBM® service web site. | |
| HSCF0032 | Unable to contact the IBM support system. | |
| HSCF0033 | Unable to contact the FTP site. | |
| HSCF0034 | Unable to log into the FTP site using the specified user ID and password. | |
| HSCF0035 | Unable to access the specified FTP site directory. | |
| HSCF0036 | The connection to the target was lost during a reboot of the FSP. | |
| HSCF0037 | Licensed Internal code was changed as requested, but a failure occurred returning the managed system to its original state. | |
| HSCF0038 | Retrieve of licensed internal code failed. | |
| HSCF0039 | {0} of {1} FRUs updated during phase {2} of power ACDL on {3} | |
| HSCF0040 | Power ACDL started on {0}. | |
| HSCF0041 | Licensed Internal Code update cannot be started because ACDL is pending on {0}. | |
| HSCF0042 | Licensed Internal Code update cannot be started because {0} has N mode power. | The system has power to only one of the two AC power cords. In general, N mode power means the system is not operating in a redundant state (N+1 power means the system can survive the loss of that particular power component). If both line cords are not powered, only one Bulk Power Controller (BPC) will be powered. Both BPCs need to be powered to load LIC. |
| HSCF0043 | The installation type for Managed System and Power LIC
indicates to install and activate disruptively. I/O LIC cannot be updated
when that installation type is selected. Ensure that either the I/O LIC checkbox is not checked, or click the Back button and ensure that the Managed System and Power LIC checkbox is not checked. When the LIC update completes, you can restart the Change Internal Code wizard to install the other LIC updates. |
|
| HSCF0044 | Select a single row in the table, and try the operation again. | |
| HSCF0045 | Firmware update was successful to all primary service processors for the targeted object. There was a failure attempting to update the backup service processor for {0}. | |
| HSCF0046 | Firmware update was successful to all primary service processors for the targeted object. There was a failure attempting to update I/O microcode on {0}. | |
| HSCF0047 | This message was used temporarily in a previous release only. | |
| HSCF0048 | Power code download failed. | |
| HSCF0049 | Failure downloading file {0} from the IBM service web site. | |
| HSCF0050 | The repository does not contain any applicable upgrade updates. | |
| HSCF0051 | There is a new upgrade release available at the repository. | |
| HSCF0052W | The frame is locked by another process and cannot run another process. | To clear this condition, run the rmlock -e command from the HMC command line. For example, rmlock -e 9458-100*918002M. |
| HSCF0071E | Communication error to Side A|B BPC on tttt-mmm*ssssssss: No connection exists. | There is no connection data found for the Bulk Power Controller. |
| HSCF0071E | Communication error to Side A|B BPC on tttt-mmm*ssssssss: Surveillance command failed. |
|
| HSCF0071E | Communication error to Primary|Secondary FSP on tttt-mmm*ssssssss: No connection exists. |
|
| HSCF0071E | Communication error to Primary|Secondary FSP on tttt-mmm*ssssssss: Surveillance command failed. |
|
| HSCF0079E | Managed system state state on ttt-mmmm*ssssssss
is incorrect. Valid states are: Operating, Power Off, Error – Terminated, Standby. |
|
| HSCF0080E | Side A|B BPC on tttt-mmm*ssssssss has failed a redundancy test. |
|
| HSCF0081E | ACDL is pending for Side A|B BPC on tttt-mmm*ssssssss. |
|
| HSCF0082E | Side A|B BPC on tttt-mmm*ssssssss has reported an error
condition: reason. Reason could be one of the following: Fault indicator is true All Good indicator is false Mailbox Present indicator is false BPF Good indicator is false |
|
| HSCF0083E | Primary FSP on tttt-mmm*ssssssss has reported an error
condition: reason. Reason could be one of the following: Secondary FSP is not functional Secondary FSP is guarded |
|