Migrating the Virtual I/O Server
You can migrate the Virtual I/O Server (VIOS) from version 1.x to version 2.x in the Hardware Management Console (HMC) Version 7, or later, from a DVD device that is attached to the Virtual I/O Server logical partition. To migrate the Virtual I/O Server from VIOS version 2.x to version 3.x, or later, use the viosupgrade command.
- The system on which you plan to migrate the Virtual I/O Server is managed by a Hardware Management Console (HMC) Version 7, or later.
- The Virtual I/O Server is at Version 1.3, or later.
- The rootvg volume group is assigned to the Virtual I/O Server.
Usually, user configuration files from the previous version of the Virtual I/O Server are saved when the new version is installed. If you have two or more Virtual I/O Server logical partitions in your environment for redundancy, you are able to shut down and migrate one Virtual I/O Server logical partition without interrupting any clients. After the migration is complete and the Virtual I/O Server logical partition is running again, the logical partition will be available to clients without additional configuration.