SRC formats
SRC formats describe the SRC record structure.
The control panel automatically displays the first word of the SRC and the extended word 1 data in Function 11 when the panel shows an SRC (see Word 1 - SRC general information). You can select other SRC words (Functions 12 through 19) by using the control panel Increment (↑), Decrement (↓), and Enter buttons. Some portions of the SRC might not contain data. SRC records vary in length (up to 36 bytes for words 1 through 9 and there may be up to 24 bytes of extended word 1 data) and display as described in the following sections.
SRC
records show with a -3 next to the function number
in the Function/Data display on System Units (for example, 11-3 xxxx xxxx).
The SRC record structure provides information about the machine at the time of the failure.
Example SRC record structure
| SRC word or FRU call-out data | Control panel function | Display characters | Format | Description |
|---|---|---|---|---|
| 1 | 11 | 1–8 | Axxx uuuu Bxxx uuuu |
uuuu = unit reference code If any of these SRCs appears in a serviceable event view or in the control panel, the operator or service provider must take some action. |
| 1 | 11 | 1–8 | Cxxx uuuu Dxxx uuuu |
uuuu = unit reference
code Initial program load (IPL) progress codes. |
| 1 – extended SRC information | 11 | 9–32 | text | Additional text about the failure. This text varies by SRC. |
| 2 | 12 | 1–8 | MIGVEPff | See Hardware SRC formats for details. |
| 3 | 12 | 9–16 | Hexadecimal data | Varies by SRC format. See Hardware SRC formats for details. |
| 4 | 12 | 17–24 | ||
| 5 | 12 | 25–32 | ||
| 6 | 13 | 1–8 | ||
| 7 | 13 | 9–16 | ||
| 8 | 13 | 17–24 | ||
| 9 | 13 | 25–32 | ||
| Replacement priority | 14–19 | 1–2 | Hexadecimal data | FRU call-out data. Displays the replacement priority, part number, part type, and location code. |
| Part number | 14–19 | 3–9 | ||
| Part type | 14–19 | 13–16 | ||
| Location code | 14–19 | 17–32 |