Function 75: Reboot Service Processor

This function is available only in the manual operation mode when the customer extended (CE) function ranges are enabled. This function reboots the service processor.

Complete the following steps to reboot the service processor:
  1. Select Function 75, and press Enter. A confirmation system reference code (SRC) such as A1003075 is displayed on the screen.
  2. Press Enter again to confirm the reboot operation. The message REBOOTING BMC is displayed, and the service processor reboots.
Note: This function is not available in the 9080-HEX system.
The following table shows an example of function 75:
Table 1. Function 75: Reboot Service Processor
Function/Data Action or description
7 5 _ _ _ _ _ _ _ _ _ _ _ _ _ _ 
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Use the Increment or Decrement buttons to scroll to function 75.
A 1 0 0 3 0 7 5 _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Press Enter on denounce to acknowledge the intent of rebooting the BMC.
R E B O O T I N G _ B M C _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Press Enter to reboot the BMC.