USE_NRZI_ENCODING

Required? No
Keyword Type Boolean
Default 0
Multiples Allowed? No, only one for each PORT_X25_SPECIFIC_DATA parameter
The USE_NRZI_ENCODING specifies how synchronous data sent to the modem is encoded. Valid values are:
0
Use non-return-to-zero (NRZ) encoding.
1
Use non-return-to-zero inverted (NRZI) encoding.

This parameter is optional. The default is 0.